Multiresolution imaging in elastography
- 1 January 1998
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 45 (1) , 65-75
- https://doi.org/10.1109/58.646912
Abstract
The range of strains that can be imaged by any practical elastographic imaging system is inherently limited, and a performance measure is valuable to evaluate these systems from the signal and noise properties of their output images. Such a measure was previously formulated for systems employing cross-correlation based time-delay estimators through the strain filter. While the strain filter predicts the signal-to-noise ratio (SNR/sub e/) for each tissue strain in the elastogram and provides valuable insights into the nature of image noise, it understated the effects of image resolution (axial resolution, as determined by the cross-correlation window length) on the noise. In this work, the strain filter is modified to study the strain noise at multiple resolutions. The effects of finite window length on signal decorrelation and on the variance of the strain estimator are investigated. Long-duration windows are preferred for improved sensitivity, dynamic range, and SNR/sub e/. However, in this limit the elastogram is degraded due to poor resolution. The results indicate that for nonzero strain, a window length exists at which the variance of strain estimator attains its minima, and consequently the elastographic sensitivity, dynamic range and SNR/sub e/ are strongly affected by the selected window length. Simulation results corroborate the theoretical results, illustrating the presence of a window length where the strain estimation variance is minimized for a given strain value. Multiresolution elastography, where the strain estimate with the highest SNR/sub e/ obtained by processing the pre- and post-compression waveforms at different window lengths is used to generate a composite elastogram and is proposed to improve elastograms. All the objective elastogram parameters (namely: SNR/sub e/, dynamic range, sensitivity and the average elastographic resolution-defined as the cross-correlation window length) are improved with multiresolution elastography when compared to the traditional method of utilizing a single window length to generate the elastogram. Experimental results using a phantom with a hard inclusion illustrates the improvement in elastogram obtained using multiresolution analysis.Keywords
This publication has 18 references indexed in Scilit:
- Error analysis in acoustic elastography. II. Strain estimation and SNR analysisThe Journal of the Acoustical Society of America, 1997
- A theoretical framework for performance characterization of elastography: the strain filterIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1997
- Deformation models and correlation analysis in elastographyThe Journal of the Acoustical Society of America, 1996
- Theoretical bounds on strain estimation in elastographyIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1995
- A fundamental limit on delay estimation using partially correlated speckle signalsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1995
- A fundamental limit on the accuracy of speckle signal alignmentPublished by Institute of Electrical and Electronics Engineers (IEEE) ,1994
- Relationship of Ultrasonic Spectral Parameters to Features of Tissue MicrostructureIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1987
- Fundamental limitations in passive time-delay estimation--Part II: Wide-band systemsIEEE Transactions on Acoustics, Speech, and Signal Processing, 1984
- An overview on the time delay estimate in active and passive systems for target localizationIEEE Transactions on Acoustics, Speech, and Signal Processing, 1981
- The generalized correlation method for estimation of time delayIEEE Transactions on Acoustics, Speech, and Signal Processing, 1976