Esophageal Luminal Temperature Measurement Underestimates Esophageal Tissue Temperature During Radiofrequency Ablation Within the Canine Left Atrium: Comparison Between 8 mm Tip and Open Irrigation Catheters
- 28 June 2008
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 19 (6) , 641-644
- https://doi.org/10.1111/j.1540-8167.2008.01130.x
Abstract
Evaluation of luminal temperature during left atrial ablation is used clinically; however, luminal temperature does not necessarily reflect temperature within the esophageal wall and poses a risk of atrioesophageal fistula. This animal study evaluates luminal esophageal temperature and its relation to the temperature of the external esophageal tissue during left atrial lesions using the 8 mm solid tip and the open irrigated tip catheters (OIC). A thermocouple was secured to the external surface of the esophagus at the level of the left atrium of the dogs. Luminal esophageal temperature was measured using a standard temperature probe. In four randomized dogs, lesions were placed using an 8 mm solid tip ablation catheter. In six randomized dogs, lesions were placed using the 3.5 mm OIC. The average peak esophageal tissue temperature when using the OIC was significantly higher than that of the 8 mm tip catheter (88.6 degrees C +/- 15.0 degrees C vs. 62.3 degrees C +/- 12.5 degrees C, P < 0.05). Both OIC and 8 mm tip catheter had significantly higher peak tissue temperatures than luminal temperatures (OIC: 88.6 degrees C +/- 15.0 degrees C vs 39.7 degrees C +/- 0.82 degrees C, P < 0.05) (8 mm: 62.3 degrees C +/- 12.5 degrees C vs 39.0 +/- 0.5 degrees C, P < 0.05). Both catheters achieved peak temperatures faster in the tissue as compared to the lumen of the esophagus, although the tissue temperature peaked significantly faster for the OIC (OIC: 25 seconds vs 90 seconds, P < 0.05) (8 mm: 63 seconds vs 105 seconds, P < 0.05). Despite the significant difference in actual tissue temperatures, no significant difference was observed in luminal temperatures between the OIC and 8 mm tip catheter.Keywords
This publication has 14 references indexed in Scilit:
- Atrial Fibrillation Ablation with Esophageal Cooling with a Cooled Water‐Irrigated Intraesophageal Balloon: A Pilot StudyJournal of Cardiovascular Electrophysiology, 2006
- Rapid Detection and Successful Treatment of Esophageal Perforation After Radiofrequency Ablation of Atrial Fibrillation: Lessons from Five CasesJournal of Cardiovascular Electrophysiology, 2006
- Movement of the Esophagus During Left Atrial Catheter Ablation for Atrial FibrillationJournal of the American College of Cardiology, 2005
- Left Atrial-Esophageal Fistula Complicating Radiofrequency Catheter Ablation of Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2005
- Computed Tomographic Analysis of the Anatomy of the Left Atrium and the EsophagusCirculation, 2004
- Esophageal Migration During Left Atrial Catheter Ablation for Atrial FibrillationCirculation, 2004
- Atrio-Esophageal Fistula as a Complication of Percutaneous Transcatheter Ablation of Atrial FibrillationCirculation, 2004
- Esophageal perforation during left atrial radiofrequency ablation: is the risk too high?The Journal of Thoracic and Cardiovascular Surgery, 2003
- Esophageal perforation during left atrial radiofrequency ablation: Is the risk too high?The Journal of Thoracic and Cardiovascular Surgery, 2003
- Esophageal injury during radiofrequency ablation for atrial fibrillationThe Journal of Thoracic and Cardiovascular Surgery, 2001