Stopping power data for high-energy photon beams
- 1 August 1986
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 31 (8) , 839-858
- https://doi.org/10.1088/0031-9155/31/8/002
Abstract
Spencer-Attix stopping power ratios for the dosimetry of high-energy photon beams used in radiation therapy have been calculated using the Monte Carlo method. The stopping power ratios are calculated in a more consistent way than previously and are given as a function of the attenuation properties of the beam. The dependence of the stopping power ratio on the electron contamination of the beam as well as on depth and field size has also been investigated. Results are compared with stopping power ratios recommended in different dosimetry protocols and to experimental results. The agreement with most dosimetry protocols is within about one per cent and with recent experimental data is better than half a per cent.This publication has 29 references indexed in Scilit:
- Determination of the photon spectrum of a clinical acceleratorMedical Physics, 1984
- Restricted Energy-Loss Straggling and Multiple Scattering of Electrons in Mixed Monte Carlo ProceduresRadiation Research, 1984
- On the selection of stopping‐power and mass energy‐absorption coefficient ratios for high‐energy x‐ray dosimetryMedical Physics, 1984
- 42 MeV bremsstrahlung spectrum analysis by a photoactivation methodNuclear Instruments and Methods in Physics Research, 1984
- A protocol for the determination of absorbed dose from high‐energy photon and electron beamsMedical Physics, 1983
- Dosis: A computer program for the calculation of absorbed dose in photon and electron beams from ionization measurements in a phantomNuclear Instruments and Methods in Physics Research, 1983
- Tissue phantom ratios for a Clinac 4/100Medical Physics, 1982
- Mean energy in electron beamsMedical Physics, 1981
- X‐ray beam characteristics of the Varian Clinac 6‐100 linear acceleratorMedical Physics, 1980
- X-Ray Spectra from Accelerators in the range 2 to 6 MeVPhysics in Medicine & Biology, 1967