Implications of using thermocouple thermometry in 27 MHz capacitively coupled interstitial hyperthermia
- 1 April 1997
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 42 (4) , 637-650
- https://doi.org/10.1088/0031-9155/42/4/003
Abstract
The 27 MHz Multi Electrode Current Source (MECS) interstitial hyperthermia system uses segmented electrodes, 10-20 mm long, to steer the 3D power deposition. This power control at a scale of 1-2 cm requires detailed and accurate temperature feedback data. To this end seven-point thermocouples are integrated into the probes. The aim of this work was to evaluate the feasibility and reliability of integrated thermometry in the 27 MHz MECS system, with special attention to the interference between electrode and thermometry and its effect on system performance. We investigated the impact of a seven-sensor thermocouple probe (outer diameter 150 microns) on the apparent impedance and power output of a 20 mm dual electrode (O.D. 1.5 mm) in a polyethylene catheter in a muscle equivalent medium (sigma 1 = 0.6 S m-1). The cross coupling between electrode and thermocouple was found to be small (1-2 pF) and to cause no problems in the dual-electrode mode, and only minimal problems in the single-electrode mode. Power loss into the thermometry system can be prevented using simple filters. The temperature readings are reliable and representative of the actual tissue temperature around the electrode. Self-heating effects, occurring in some catheter materials, are eliminated by sampling the temperature after a short power-off interval. We conclude that integrated thermocouple thermometry is compatible with 27 MHz capacitively coupled interstitial hyperthermia. The performance of the system is not affected and the temperatures measured are a reliable indication of the maximum tissue temperatures.Keywords
This publication has 12 references indexed in Scilit:
- Ultrasound applicators with integrated catheter-cooling for interstitial hyperthermia: Theory and preliminary experimentsInternational Journal of Hyperthermia, 1996
- A 3-D SAR model for current source interstitial hyperthermiaIEEE Transactions on Biomedical Engineering, 1996
- Dose uniformity in scanned focused ultrasound hyperthermiaInternational Journal of Hyperthermia, 1994
- Temperature and SAR measurements in deep-body hyperthermia with thermocouple thermometryInternational Journal of Hyperthermia, 1993
- Temperature uniformity during hyperthermia: the impact of large vesselsPhysics in Medicine & Biology, 1992
- Interstitial heating: experiments in artificially perfused bovine tonguesPhysics in Medicine & Biology, 1991
- RTOG quality assurance guidelines for interstitial hyperthermiaInternational Journal of Radiation Oncology*Biology*Physics, 1991
- Application of a capacitive-coupling interstitial hyperthermia system at 27 MHz: study of different applicator configurationsPhysics in Medicine & Biology, 1991
- Practical interstitial method of heating operating at 27.12 MHzInternational Journal of Hyperthermia, 1989
- The accuracy of temperature measurement from within an interstitial microwave antennaInternational Journal of Hyperthermia, 1988