Regional lung hematocrit in humans using positron emission tomography
- 31 March 1986
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 60 (4) , 1155-1163
- https://doi.org/10.1152/jappl.1986.60.4.1155
Abstract
Regional lung hematocrit ratio (R) was measured in five normal subjects and five patients (2 with pneumonia, 2 with nephrotic syndrome with anemia, and 1 with pancreatitis) using positron emission tomography, a red cell marker 11CO, and a plasma marker [methyl-11C]albumin). The measurements were made in a transaxial thoracic section at midheart level with the subject in supine posture and with a spatial resolution of 1.7 cm. The normal regional hematocrit ratio (means +/- SE) calculated for the lung was 0.90 +/- 0.014, 0.94 +/- 0.023 for the thoracic wall, and 1.00 +/- 0.003 for the heart chambers. The regional lung hematocrit ratio in the patients ranged between 0.81 and 0.86. No correlation was found among the regional lung hematocrit ratio and regional blood volume, lung extravascular density, and the peripheral hematocrit (obtained from venous blood samples). To the extent that 70% of the pulmonary blood in the field of view is in larger vessels with normal hematocrit, the hematocrit in the capillary bed is approximately two-thirds that of the peripheral venous value. Blood volume measurements on the basis of single vascular tracers need to take account of these results.This publication has 8 references indexed in Scilit:
- In vivo Measurement of Regional Cerebral Haematocrit Using Positron Emission TomographyJournal of Cerebral Blood Flow & Metabolism, 1984
- Regional extravascular density and fractional blood volume of the lung in interstitial disease.Thorax, 1984
- Quantitative Measurement of Regional Extravascular Lung Density Using Positron Emission and Transmission TomographyJournal of Computer Assisted Tomography, 1981
- Regional extravascular and interstitial lung water in normal dogsJournal of Applied Physiology, 1980
- Relative Importance of Diffusion and Chemical Reaction Rates in Determining Rate of Exchange of Gases in the Human Lung, With Special Reference to True Diffusing Capacity of Pulmonary Membrane and Volume of Blood in the Lung CapillariesJournal of Applied Physiology, 1957
- Distribution of Blood (Fe 59 ) and Plasma (I 131 ) Volumes of Rats Determined by Liquid Nitrogen FreezingCirculation Research, 1956
- THE BODY/VENOUS HEMATOCRIT RATIO: ITS CONSTANCY OVER A WIDE HEMATOCRIT RANGEJournal of Clinical Investigation, 1953
- THE SUSPENSION STABILITY OF THE BLOODPhysiological Reviews, 1929