Derivation of synchronous machine parameters from tests
- 1 July 1977
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Apparatus and Systems
- Vol. 96 (4) , 1211-1218
- https://doi.org/10.1109/t-pas.1977.32443
Abstract
This paper describes a test procedure for derivation of synchronous machine parameters. The tests can be conducted with ease and without hazard on generators in utility systems. Unlike textbook methods involving short circuit and slip tests which are inconvenient and hazardous, the proposed method involves simple procedures, which can be implemented in normal operation of the machine.Keywords
This publication has 4 references indexed in Scilit:
- Determination of synchronous-machine parameters allowing for unequal mutual inductancesProceedings of the Institution of Electrical Engineers, 1974
- Dynamic Models of Turbine Generators Derived From Solid Rotor Equivalent CircuitsIEEE Transactions on Power Apparatus and Systems, 1973
- Experimental Determination of Exact Equivalent Circuit Parameters of Synchronous MachinesIEEE Transactions on Power Apparatus and Systems, 1971