Intrastromal Corneal Ring: 12-month Sighted Myopic Eyes
- 1 January 1996
- journal article
- clinical trial
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 12 (1) , 20-28
- https://doi.org/10.3928/1081-597x-19960101-08
Abstract
BACKGROUND: To evaluate the efficacy, predictability, and stability of the refractive effect produced by the Intrastromal Corneal Ring (ICR®), the authors completed a 12-month study on 10 myopic eyes. METHODS: Ten patients with preoperative refractive errors ranging from -2.63 diopters (D) to -4.25 D (mean, -3.30 D) participated in the study. The attempted correction was -2.50 D for a 7.0-mm diameter, 0.3-mm thick ICR. One eye of each patient received an ICR. RESULTS: The average change in spherical equivalent at 12 months was -2.25 D (SD 0.54 D; range, -1.62 to -3.25 D). All patients maintained a spectacle-corrected visual acuity of 20/20 or better during the 12-month study period, with the exception of patient no. 6 who saw 20/30 at the 6-month examination. Her spectacle-corrected visual acuity returned to 20/20 a few days after the ICR was explanted and remained stable throughout the study. Uncorrected visual acuity had improved to 20/40 or better in all patients on postoperative day 1 and remained in this range for the 9 eyes (90%) during the 12 months of follow up. At postoperative month 12, 9 of 9 eyes (100%) had an uncorrected visual acuity of 20/40 or better with 3 of 9 eyes (33%) seeing 20/20 or better. The remaining patient, no. 6, experienced a tear in Descemet's membrane during the procedure and required explantation of the ring after 6 months due to induced astigmatism and deterioration of uncorrected visual acuity. Two patients developed infiltrates that resolved with the use of antibiotics. The most common postoperative ocular findings were peripheral corneal haze in all eyes that diminished over time, minute lamellar channel deposits (7 of 10 eyes, 70%), deep stromal neovascularization (5 of 10 eyes, 50%), and pannus (5 of 10 eyes, 50%). CONCLUSION: This preliminary study shows that implantation of an intrastromal corneal ring of this dimension (0.3-mm thick) can reduce approximately 1.50 to 3.00 D of myopia and maintain spectacle-corrected visual acuity. [J Refract Surg. 1996;12:20-28.]Keywords
This publication has 10 references indexed in Scilit:
- Intrastromal Corneal Ring-One-Year Results of First Implants in Humans: A Preliminary Nonfunctional Eye StudyJournal of Refractive Surgery, 1993
- Corneal Iron Lines Associated With the Intrastromal Corneal RingAmerican Journal of Ophthalmology, 1993
- Flattening of central corneal curvature with Intrastromal Corneal Rings of increasing thickness: An eye-bank eye studyJournal of Cataract & Refractive Surgery, 1993
- The Relationship of Visual Acuity, Refractive Error, and Pupil Size After Radial KeratotomyArchives of Ophthalmology (1950), 1991
- Should Refractive Surgeons Worry About Corneal Asphericity?Journal of Refractive Surgery, 1990
- Lipid Deposits Posterior to Impermeable Intracorneal Lenses in Rhesus Monkeys: Clinical, Histochemical, and Ultrastructural StudiesJournal of Refractive Surgery, 1990
- The Intrastromal Corneal Ring: Two Cases in RabbitsJournal of Refractive Surgery, 1987
- Stellate Iron Lines in the Corneal Epithelium After Radial KeratotomyAmerican Journal of Ophthalmology, 1984
- Iron Deposition in the Corneal GraftArchives of Ophthalmology (1950), 1983
- Corneal Iron Lines After Refractive KeratoplastyArchives of Ophthalmology (1950), 1983