New Technique to Extend the Useful Life of a Biodegradable Cartilage Implant
- 1 December 1998
- journal article
- research article
- Published by Mary Ann Liebert Inc in Tissue Engineering
- Vol. 4 (4) , 343-352
- https://doi.org/10.1089/ten.1998.4.343
Abstract
Biodegradable implants made of α-hydroxypolyesters, such as polylactic acid, polyglycolic acid, or their copolymers, undergo bulk degradation with a concomitant mass loss. Although biocompatibility or toxicity problems, which have occasionally been reported in response to these materials' in vivo behavior, have not been conclusively linked to rapid mass loss, we hypothesized that such implants should degrade and lose mass in a more uniform rate. To this end, we designed a new implant, intended to be used in articular cartilage repair, consisting of a blend of three copolymers of 50:50 poly(D,L)-lactide coglycolide with inherent viscosities of 0.23, 0.58, and 1.37 dL/g. The objective of the blend implant design was to achieve a slower rate of degradation and mass loss in comparison to a previous design, which used a single copolymer of inherent viscosity of 0.58 dL/g. The blend's in vitro degradation characteristics were obtained and compared to those of the control design in terms of mass, molecular weight, pH, mechanical properties, gross morphology, and porosity. Another objective of our study was to design and employ a novel test for assessing the permeability of porous scaffolds, using a custom apparatus under direct permeation conditions. Significant differences in the temporal behavior of the two groups were found. The blend implants maintained their overall structural integrity longer than control specimens (6 weeks versus 3 weeks). This was a surprising finding in light of the fact that losses in molecular weight were similar in the two groups. Extension of structural usefulness to 6 weeks, achieved by the method described in the study, can be expected to enhance the viability of this scaffold in an in vivo application such as cartilage repair. Thus, the blended copolymer implants may be more suitable in orthopedic applications, where a decreased degradation rate would be preferable.Keywords
This publication has 17 references indexed in Scilit:
- Elevated Temperature Degradation of a 50:50 Copolymer of PLA-PGATissue Engineering, 1997
- The Effects of Dynamic Compressive Loading on Biodegradable Implants of 50–50% Polylactic Acid–Polyglycolic AcidTissue Engineering, 1996
- Degradation of polydispersed poly(l-lactic acid) to modulate lactic acid releaseBiomaterials, 1995
- Comparative study of the intrinsic mechanical properties of the human acetabular and femoral head cartilageJournal of Orthopaedic Research, 1994
- Examination of efferent lymph nodes after 2 years of transcortical implantation of poly(L‐lactide) containing plugs: A case reportJournal of Biomedical Materials Research, 1993
- Biological response of intramedullary bone to poly‐L‐lactic acidJournal of Applied Biomaterials, 1993
- In vitro and in vivo studies on bioabsorbable ultra‐high‐strength poly(L‐lactide) rodsJournal of Biomedical Materials Research, 1992
- Biocompatibility of poly (DL-lactic acid/glycine) copolymersClinical Materials, 1991
- Degradation rates of oral resorbable implants (polylactates and polyglycolates): Rate modification with changes in PLA/PGA copolymer ratiosJournal of Biomedical Materials Research, 1977
- Resorption rate, route of elimination, and ultrastructure of the implant site of polylactic acid in the abdominal wall of the ratJournal of Biomedical Materials Research, 1973