Quantitative Measures for Fracture Healing: An In-Vitro Biomechanical Study
- 1 November 1990
- journal article
- research article
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 112 (4) , 401-406
- https://doi.org/10.1115/1.2891203
Abstract
A method is presented to assess the functional capabilities of plated osteotomized canine femora as load bearing structures and to quantify their healing status. In this method the osteotomized bones and their intact contralateral controls are tested in nondestructive bending, in twenty-four planes of loading at 15 degree angular increments. Flexural rigidity (EI), in each of the planes, is determined by using classical beam theory. It has been found that the EI values have the expected elliptical distribution. The 24 EI values, obtained for each bone, are curve fitted by regression analysis and the characteristics of each bone are described by the three parameters defining its ellipse. The parameters of the ellipses of the osteotomized bone and of its contralateral control are used to define four new parameters that may serve as measures for the healing efficiency. One of these serves as an indicator for the fragility of the healed bone and the other three add quantiative information on its mechanical state.Keywords
This publication has 13 references indexed in Scilit:
- The use of short carbon fibre reinforced thermoplastic plates for fracture fixationBiomaterials, 1985
- Refracture of bones of the forearm after plate removal.Journal of Bone and Joint Surgery, 1984
- The Stress-Protecting Effect of Metal Plates on the Intact Rabbit TibiaActa Orthopaedica, 1983
- Mechanical Properties of Fractured and Intact Rat Femora Evaluated by Bending, Torsional and Tensile TestsActa Orthopaedica, 1981
- Effects of flexural rigidity of plates on bone healing.Journal of Bone and Joint Surgery, 1979
- Effects on intact femora of dogs of the application and removal of metal plates. A metabolic and structural study comparing stiffer and more flexible plates.Journal of Bone and Joint Surgery, 1978
- Atrophy of Cortical Bone Caused by Rigid Internal Fixation Plates:An Experimental Study in the DogActa Orthopaedica, 1978
- An interdisciplinary approach to evaluate the effect of internal fixation plate on long bone remodelingJournal of Biomechanics, 1977
- Human ulnar bending stiffness, mineral content, geometry and strengthJournal of Biomechanics, 1976
- The Effects of Rigidity of Internal Fixation Plates on Long Bone Remodeling:A Bio Mechanical and Quantitative Histological StudyActa Orthopaedica, 1976