Contrast-detail evaluation and dose assessment of eight digital chest radiography systems in clinical practice
- 31 August 2005
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 16 (2) , 333-341
- https://doi.org/10.1007/s00330-005-2887-6
Abstract
The purpose of this study was to assess contrast-detail performance and effective dose of eight different digital chest radiography systems. Digital chest radiography systems from different manufacturers were included: one storage phosphor system, one selenium-coated drum system, and six direct readout systems including four thin-film transistor (TFT) systems and two charge-coupled device (CCD) systems. For measuring image quality, a contrast-detail test object was used in combination with a phantom that simulates the primary and scatter transmission through lung fields (LucAl). Six observers judged phantom images of each modality by soft-copy reading in a four-alternative-forced-choice experiment. The entrance dose was also measured, and the effective dose was calculated for an average patient. Contrast-detail curves were constructed from the observer data. The blocked two-way ANOVA test was used for statistical analysis. Significant difference in contrast-detail performance was found between the systems. Best contrast-detail performance was shown by a CCD system with slot-scan technology, and the selenium-coated drum system was compared to the other six systems (p values ≤0.003). Calculated effective dose varied between 0.010 mSv and 0.032 mSv. Significant differences in contrast-detail performance and effective dose levels were found between different digital chest radiography systems in clinical practice.Keywords
This publication has 30 references indexed in Scilit:
- Dose Reduction in Patients Undergoing Chest Imaging: Digital Amorphous Silicon Flat-Panel Detector Radiography Versus Conventional Film-Screen Radiography and Phosphor-Based Computed RadiographyAmerican Journal of Roentgenology, 2003
- The value of scatter removal by a grid in full field digital mammographyMedical Physics, 2003
- Digital radiography with large-area flat-panel detectorsEuropean Radiology, 2002
- Selenium-Based Digital Radiography Versus High-Resolution Storage Phosphor Radiography in the Detection of Solitary Pulmonary Nodules Without CalcificationAmerican Journal of Roentgenology, 2001
- Digital Chest Radiography with a Selenium-Based Flat-Panel Detector Versus a Storage Phosphor SystemAmerican Journal of Roentgenology, 2000
- Digital selenium radiography: anti-scatter grid for chest radiography in a clinical study.The British Journal of Radiology, 2000
- Organ Dose Calculation in Medical X Ray Examinations by the Program PCXMCRadiation Protection Dosimetry, 1998
- Chest radiographic image quality: comparison of asymmetric screen-film, digital storage phosphor, and digital selenium drum systems--preliminary study.RadioGraphics, 1998
- Quality analysis of DSA equipmentNeuroradiology, 1988
- Beam quality independent attenuation phantom for estimating patient exposure from x-ray automatic exposure controlled chest examinationsMedical Physics, 1984