The Utility of Isokinetic Dynamometry in the Assessment of Human Muscle Function
- 1 January 1996
- journal article
- review article
- Published by Springer Nature in Sports Medicine
- Vol. 21 (1) , 18-34
- https://doi.org/10.2165/00007256-199621010-00003
Abstract
Isokinetic dynamometry has become a favoured method for the assessment of dynamic muscle function in both clinical research and sports environments. Several indices, such as peak torque, are used in the literature to characterise individual, group or larger population performance via these sophisticated data acquisition systems. Research suggests that there are several competing demands on the design of the measurement protocol which may affect the measurement of isokinetic strength and subsequent suitability of data for meaningful evaluation and interpretation. There is a need to increase measurement rigour, reliability and sensitivity to a level which is commensurate with the intended application, via more elaborate multiple-trial protocols. However, this may be confounded by logistical and financial constraints or reduced individual compliance. The net effect of the interaction of such demands may be considered to be the utility of the isokinetic dynamometry protocol. Of the factors which impinge on utility, those which relate to reliability afford the most control by the test administrator. Research data suggest that in many measurement applications, the reliability and sensitivity associated with all frequently-used indices of isokinetic leg strength which are estimated via single-trial protocols, are not sufficient to differentiate either performance change within the same individual or between individuals within a homogeneous group. While such limitations may be addressed by the use of protocols based on 3 to 4 inter-day trials for the index of peak torque, other indices which demonstrate reduced reliability, for example the composite index of the ratio of knee flexion to extension peak torque, may require many more replicates to achieve the same level of sensitivity. Here, the measurement utility of the index may not be sufficient to justify its proper deployment.Keywords
This publication has 56 references indexed in Scilit:
- The effect of range of motion and isometric pre-activation on isokinetic torquesEuropean Journal of Applied Physiology, 1991
- The relationship between peak torque and work of the quadriceps and hamstrings after knee injury.1990
- Kinanthropometry: Roots, developments and futureJournal of Sports Sciences, 1990
- Reliability of an Isokinetic Test of Muscle Strength and EnduranceJournal of Orthopaedic & Sports Physical Therapy, 1989
- Eccentric and Concentric Torque-Velocity Characteristics, Torque Output Comparisons, and Gravity Effect Torque Corrections for the Quadriceps and Hamstring Muscles in FemalesInternational Journal of Sports Medicine, 1989
- A new dynamometer measuring concentric and eccentric muscle strength in accelerated, decelerated, or isokinetic movementsEuropean Journal of Applied Physiology, 1988
- Determination of dynamic muscle strength in man with acceleration controlled isokinetic movementsActa Physiologica Scandinavica, 1983
- Electromyographic, Peak Torque, and Power Relationships During Isokinetic MovementPTJ: Physical Therapy & Rehabilitation Journal, 1983
- Comparison of Isokinetic Measurements with Test RepetitionsPTJ: Physical Therapy & Rehabilitation Journal, 1982
- LEG EXTENSION POWER AND MUSCLE-FIBER COMPOSITION1979