Transcranial Doppler Monitoring of Transcervical Carotid Stenting With Flow Reversal Protection
- 1 November 2006
- journal article
- research article
- Published by Wolters Kluwer Health in Stroke
- Vol. 37 (11) , 2846-2849
- https://doi.org/10.1161/01.str.0000244781.68371.59
Abstract
Background and Purpose—Transfemoral carotid stenting, despite becoming very frequent, has some limitations such as difficult groin access in few patients, lack of distal protection during filter placement, or embolization despite protection. Transcervical stenting (TCS) is a novel technique during which a common carotid to jugular vein shunt is placed creating a protective reversal flow in the internal carotid artery after proximal common carotid artery (CCA) clamping. We aim to study, with transcranial Doppler (TCD), cerebral flow changes and microemboli detection during transcervical stenting.Methods—From September 2005 to March 2006, of 65 consecutive patients eligible for carotid revascularization, 23 were considered high risk (sapphire criteria) and underwent TCS. Neurologic examination was performed before and after the procedure by a neurologist and a preprocedure vascular reactivity TCD examination was done in all patients.Results—After CCA clamping, flow inversion was observed in the anterior cerebral artery, supplying blood to the middle cerebral artery (MCA) and internal carotid artery (reversal). TCD did not detect any air/solid emboli during stent deployment and angioplasty confirming the reversal flow protection hypothesis. Mean reversal flow time was 15.4 minutes; in all cases, substantial MCA flow was present during CCA clamping (initial mean velocity 30 cm/s), and a slow gradual increase was observed traducing collateral flow recruitment (mean velocity after 5 minutes 36 cm/s,PP=0.036). The only in-procedure complication was one transient ischemic attack. After CCA unclamping, normal antegrade flow was restored in anterior cerebral artery and mean final MCA velocity increased 16% according to preprocedure flow.Conclusions—TCS with protective internal carotid artery flow reversal can eliminate showers of micoremboli during stent deployment making it a promising carotid revascularization technique in high-risk patients with carotid stenosis.Keywords
This publication has 14 references indexed in Scilit:
- Vessel Wall Damage Caused by Cerebral Protection Devices: Ex Vivo Evaluation in Porcine Carotid ArteriesRadiology, 2005
- Carotid Angioplasty and Stent Placement: Comparison of Transcranial Doppler US Data and Clinical Outcome with and without Filtering Cerebral Protection Devices in 509 PatientsRadiology, 2005
- Protected Carotid-Artery Stenting versus Endarterectomy in High-Risk PatientsNew England Journal of Medicine, 2004
- Transcervical carotid stenting with internal carotid artery flow reversal: Feasibility and preliminary resultsJournal of Vascular Surgery, 2004
- Transcervical Carotid Artery Angioplasty and Stenting with Carotid Flow Reversal: Surgical TechniqueAnnals of Vascular Surgery, 2004
- Cerebrovascular Ultrasound in Stroke Prevention and TreatmentPublished by Wiley ,2004
- Carotid Angioplasty and Stenting With and Without Cerebral ProtectionStroke, 2004
- Early Outcome of Carotid Angioplasty and Stenting With and Without Cerebral Protection DevicesStroke, 2003
- Insonation Method and Diagnostic Flow Signatures for Transcranial Power Motion (M-Mode) DopplerJournal of Neuroimaging, 2002
- Initial evaluation of carotid angioplasty and stenting with three different cerebral protection devicesJournal of Vascular Surgery, 2000