Detection of bacteria in platelet concentrates: comparison of broad‐range real‐time 16S rDNA polymerase chain reaction and automated culturing
- 11 April 2005
- journal article
- Published by Wiley in Transfusion
- Vol. 45 (5) , 731-736
- https://doi.org/10.1111/j.1537-2995.2005.04258.x
Abstract
BACKGROUND: Based on real-time polymerase chain reaction (PCR) technology, a broad-range 16S rDNA assay was validated and its performance was compared to that of an automated culture system to determine its usefulness for rapid routine screening of platelet concentrates (PCs). STUDY DESIGN AND METHODS: The presence of bacteria in pooled PCs was routinely assessed in an automated culturing system (BacT/ALERT, bioMérieux). The PCR assay was performed with DNA extracted from the same samples as used for culturing. DNA extraction was performed with a automated extraction system (MagNA Pure, Roche Diagnostics). PCR amplification was performed with a set of universal primers and probe targeting eubacterial 16S rDNA. RESULTS: A total of 2146 PCs were tested. Eighteen (0.83%) samples were found to be contaminated. These samples were positive for the presence of bacteria by both methods. All contaminants were identified as bacteria belonging to the common human skin flora. These included Propionibacterium spp. (n = 7), Staphylococcus spp. (n = 6), Bacillus spp. (n = 2), Micrococcus spp. (n = 2), and Peptostreptococcus spp. (n = 1). Estimation of the bacterial load in PCs by real-time PCR showed that the initial levels of contamination varied between 13.6 and 9 × 104 colony-forming unit equivalents per PCR procedure. CONCLUSIONS: Compared to culture in the BacT/ALERT system, the PCR assay had a sensitivity of 100 percent and a specificity of 100 percent. This real-time PCR assay has a much shorter turnaround time of 4 hours, which offers the possibility to test and obtain results on PCs before release or the day they are transfused. This would permit the withdrawal of contaminated PCs before transfusion.Keywords
This publication has 24 references indexed in Scilit:
- Real‐time amplification of HLA‐DQA1 for counting residual white blood cells in filtered platelet concentratesTransfusion, 2004
- Application of an rRNA Probe Matrix for Rapid Identification of Bacteria and Fungi from Routine Blood CulturesJournal of Clinical Microbiology, 2003
- International Forum: 1Vox Sanguinis, 2003
- Transfusion et bactéries : risque résiduel et perspectives de préventionTransfusion Clinique et Biologique, 2003
- Determination of the degree of bacterialcontamination of whole‐blood collections using anautomated microbe‐detection systemTransfusion, 2001
- Evaluation of an automated culture systemfor detecting bacterial contamination of platelets: an analysis with 15 contaminating organismsTransfusion, 2001
- Bacterial contamination of blood products: Factors, options, and insightsJournal of Clinical Apheresis, 2001
- Approaches to the detection of bacterial contamination in cellular blood productsTransfusion Medicine Reviews, 1999
- Real time quantitative PCR.Genome Research, 1996
- Preparation of Leukocyte-Poor Platelet Concentrates from Buffy CoatsVox Sanguinis, 1987