Is planar thallium-201/fluorine-18 fluorodeoxyglucose imaging a reasonable clinical alternative to positron emission tomographic myocardial viability scanning?
- 1 July 1995
- journal article
- clinical trial
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 22 (7) , 625-632
- https://doi.org/10.1007/bf01254563
Abstract
This comparative study was performed to determine whether a conventional planar gamma camera optimised for 511-keV imaging can reliably assess myocardial viability using the fluorine-18 fluorodeoxyglucose (FDG) metabolic tracer previously developed for positron emission tomography (PET). Twenty-seven patients with severe ischaemic cardiomyopathy (mean left ventricular ejection fraction: 20%±9%) having clinically indicated nitrogen-13 ammonia/FDG PET myocardial viability studies consented to resting, four-view, planar myocardial thallium-201 perfusion and FDG metabolism imaging. The resultant PET and planar perfusion/metabolism images (PPI) were independently assessed for FDG defect size and perfusion/metabolism mismatch, using a four-point scale, in each of four vascular regions: apex, circumflex, left anterior and posterior descending coronary artery territories. Of 108 regions, 106 were evaluable (two not assessed by PET). There was complete agreement in 70% of coronary vascular territories, giving an unweighted kappa score of 0.56. Moreover, in 94% of segments agreement was within one grade. Interestingly, six of the seven differences of more than one grade occurred in the circumflex coronary territory, which was also the only region for which planar positron imaging underestimated FDG defect size. Three of four moderate areas of perfusion/metabolism mismatch seen with PET were also seen on PPI. PPI showed three small regions of mismatch not seen on PET, whilst the reverse occurred with one other small region of mismatch. Thus, for this PET protocol, PPI provides very similar information on the extent of regional FDG uptake and occurrence of mismatch. This suggests that perfusion/FDG imaging using an adequately collimated conventional planar gamma camera may be used instead of a formal PET viability study for the clinical detection of viable myocardium, making this form of metabolic assessment more widely available throughout the community.Keywords
This publication has 24 references indexed in Scilit:
- The hibernating myocardiumPublished by Elsevier ,2004
- Value of metabolic imaging with positron emission tomography for evaluating prognosis in patients with coronary artery disease and left ventricular dysfunctionThe American Journal of Cardiology, 1994
- Current diagnostic techniques of assessing myocardial viability in patients with hibernating and stunned myocardium.Circulation, 1993
- Clinical outcome of patients with advanced coronary artery disease after viability studies with positron emission tomographyJournal of the American College of Cardiology, 1992
- Quantitative planar imaging of glucose metabolic activity in myocardial segments with exercise thallium-201 perfusion defects in patients with myocardial infarction: Comparison with late (24-hour) redistribution thallium imaging for detection of reversible ischemiaAmerican Heart Journal, 1992
- In-target production of [13N]ammonia via proton irradiation of dilute aqueous ethanol and acetic acid mixturesInternational Journal of Radiation Applications and Instrumentation. Part A. Applied Radiation and Isotopes, 1991
- Quantitative rotational thallium-201 tomography for identifying and localizing coronary artery disease.Circulation, 1988
- Stress scintigraphy using single-photon emission computed tomography in the evaluation of coronary artery diseaseThe American Journal of Cardiology, 1984
- Results of coronary artery surgery in patients with poor left ventricular function (CASS).Circulation, 1983
- Noninvasive detection of regional myocardial ischemia using rubidium-81 and the scintillation camera: comparison with stress electrocardiography in patients with arteriographically documented coronary stenosis.Circulation, 1975