Electrochemical microfluidic biosensor for the detection of nucleic acid sequences
- 24 January 2006
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 6 (3) , 414-421
- https://doi.org/10.1039/b513239h
Abstract
A microfluidic biosensor with electrochemical detection for the quantification of nucleic acid sequences was developed. In contrast to most microbiosensors that are based on fluorescence for signal generation, it takes advantage of the simplicity and high sensitivity provided by an amperometric and coulorimetric detection system. An interdigitated ultramicroelectrode array (IDUA) was fabricated in a glass chip and integrated directly with microchannels made of poly(dimethylsiloxane) (PDMS). The assembly was packaged into a Plexiglas® housing providing fluid and electrical connections. IDUAs were characterized amperometrically and using cyclic voltammetry with respect to static and dynamic responses for the presence of a reversible redox couple—potassium hexacyanoferrate (II)/hexacyanoferrate (III) (ferri/ferrocyanide). A combined concentration of 0.5 µM of ferro/ferricyanide was determined as lower limit of detection with a dynamic range of 5 orders of magnitude. Background signals were negligible and the IDUA responded in a highly reversible manner to the injection of various volumes and various concentrations of the electrochemical marker. For the detection of nucleic acid sequences, liposomes entrapping the electrochemical marker were tagged with a DNA probe, and superparamagnetic beads were coated with a second DNA probe. A single stranded DNA target sequence hybridized with both probes. The sandwich was captured in the microfluidic channel just upstream of the IDUA via a magnet located in the outside housing. Liposomes were lysed using a detergent and the amount of released ferro/ferricyanide was quantified while passing by the IDUA. Optimal location of the magnet with respect to the IDUA was investigated, the effect of dextran sulfate on the hybridization reaction was studied and the amount of magnetic beads used in the assay was optimized. A dose response curve using varying concentrations of target DNA molecules was carried out demonstrating a limit of detection at 1 fmol assay−1 and a dynamic range between 1 and 50 fmol. The overall assay took 6 min to complete, plus 15–20 min of pre-incubation and required only a simple potentiostat for signal recording and interpretation.Keywords
This publication has 32 references indexed in Scilit:
- Microfluidic Biosensor for the Serotype-Specific Detection of Dengue Virus RNAAnalytical Chemistry, 2005
- Mini-electrochemical detector for microchip electrophoresisLab on a Chip, 2005
- Home blood glucose biosensors: a commercial perspectiveBiosensors and Bioelectronics, 2005
- Development of a microfluidic biosensor module for pathogen detectionLab on a Chip, 2005
- A polymeric microchip with integrated tips and in situ polymerized monolith for electrospray mass spectrometryLab on a Chip, 2005
- Microfluidic biosensing systems : Part I. Development and optimisation of enzymatic chemiluminescent µ-biosensors based on silicon microchipsLab on a Chip, 2004
- Characterization and Optimization of Interdigitated Ultramicroelectrode Arrays as Electrochemical Biosensor TransducersElectroanalysis, 2004
- Microchip-based enzyme-linked immunosorbent assay (microELISA) system with thermal lens detectionLab on a Chip, 2004
- Theoretical treatment of the amperometric current response of multiple microelectrode arraysAnalytica Chimica Acta, 1996
- Small-volume voltammetric detection of 4-aminophenol with interdigitated array electrodes and its application to electrochemical enzyme immunoassayAnalytical Chemistry, 1993