Measurement of Rayleigh Scattering in Liquids Using Optical Fibers
- 1 August 1973
- journal article
- Published by Optica Publishing Group in Applied Optics
- Vol. 12 (8) , 1824-1827
- https://doi.org/10.1364/ao.12.001824
Abstract
Measurements have been made of Rayleigh scattering in CCl4 and C2Cl4 as a function of wavelength between 6000 Å and 10,600 Å. The scattering loss rate is 25 dB/km for CCl4 and 68 dB/km for C2Cl4 at 6328 A. The scattering loss rate follows a (wavelength)−4 dependence over the entire spectrum observed. The Rayleigh scattering was measured by placing the liquid sample in a hollow fused-quartz fiber and measuring the light scattered by the liquid through the fiber wall. It appears that this is the first time that the expected (wavelength)−4 dependence of Rayleigh scattering has actually been observed in liquids over a wide spectral range. This technique is simple and accurate and may be applied to the measurement of the scattering coefficient of any liquid whose index of refraction exceeds the cladding index of refraction (for fused quartz nD = 1.458).Keywords
This publication has 4 references indexed in Scilit:
- Optical Transmission in Liquid-Core Quartz FibersApplied Physics Letters, 1972
- Integrating Cube Scattering DetectorApplied Optics, 1970
- Temperature dependence of rayleigh light scattering and depolarization in pure liquidsJournal of Colloid and Interface Science, 1968
- Light scattering from binary mixtures of water, methanol and ethanolTransactions of the Faraday Society, 1968