Evaluation of the corneal test as a laboratory method for rabies diagnosis.
- 1 February 1973
- journal article
- research article
- Vol. 25 (2) , 187-9
Abstract
The corneal test (CT) for rabies diagnosis was evaluated in samples from 313 subjects of different species. Some of the subjects were inoculated experimentally and others were naturally infected. When the CT was compared with immunofluorescence staining and mouse inoculation tests on brains of the same subjects, a sensitivity of 41.7% and a specificity of 100% were found. The authors conclude that a positive CT result would confirm the diagnosis of rabies, but a negative one would not exclude the possibility of disease.This publication has 10 references indexed in Scilit:
- [Characteristics of a rabies virus strain isolated from the brain of Desmodus rotundus].1972
- Methods for accelerating the fluorescent-antibody test for rabies diagnosis.1971
- Rabies in a child diagnosed by a new intra-vitam method. The cornea test.1971
- A Case of Human Rabies in Kansas: Epidemiologic, Clinical, and Laboratory ConsiderationsThe Journal of Infectious Diseases, 1970
- [Study of experimental rabies of foxes].1970
- The Cornea Test; a New Method for the Intra‐vitam Diagnosis of RabiesZentralblatt für Veterinärmedizin Reihe B, 1969
- Laboratory techniques in rabies. Mouse inoculation test.1966
- Fluorescent Antibody Staining of Street and Fixed Rabies Virus AntigensExperimental Biology and Medicine, 1958
- Rabies neutralizing antibody response to different schedules of serum and vaccine inoculations in non-exposed persons.1956
- LABORATORYAmerican Journal of Public Health, 1927