Current Status of Heart Assist and Replacement in Taiwan
- 12 November 2008
- journal article
- clinical trial
- Published by Wiley in Artificial Organs
- Vol. 20 (12) , 1325-1329
- https://doi.org/10.1111/j.1525-1594.1996.tb00684.x
Abstract
The first clinical application of intraaortic balloon pumps (IABP) in Taiwan was in 1976 to treat post-cardiotomy cardiogenic shock. It is now the most commonly used circulatory assist. From 1991 to 1995, 186 patients received IABP support with an overall mortality rate 41.9%. The male patients had the best survival rate, 67%, after coronary artery bypass grafting. The first extracorporeal membrane oxygenation (ECMO) was in 1987 to treat intractable heart failure caused by severe acute rejection after heart transplantation. Because of poor outcome, patients only received ECMO sporadically during the past years. From November 1994 to November 1995, 30 patients received ECMO support with 50% of them eventually weaned from ECMO and 27% discharged. For short-term support or emergency rescue, ECMO was a good choice. When long-term support was required, the ventricular assist device (VAD) was a more suitable assist. One patient who received Thermedics VAD developed right heart failure and finally died of sepsis and multiple organ failure. VAD should be implanted before the secondary organ failure. The first successful clinical heart transplantation in Taiwan was performed on July 17, 1987. From 1991 to 1995, 102 patients underwent heart transplantation. The operative mortality was 3.9%, and the 1 and 5 year actuarial survival rates were 86 +/- 3% and 77 +/- 5%, respectively. To improve the success rate of clinical heart transplantation, organ donation should be encouraged.Keywords
This publication has 12 references indexed in Scilit:
- Comparative testing of pulsatile impeller total heart and sarns nonpulsatile roller as biventricular assist device in pigsMedical Engineering & Physics, 1996
- Haematological variations of experimental pigs during biventricular assistance with impeller total heartMedical Engineering & Physics, 1996
- In vivo testing of a pulsatile implantable impeller pump as a left ventricular assist device used in calvesPerfusion, 1995
- In Vivo Studies of Pulsatile Implantable Impeller Assist and Total HeartsArtificial Organs, 1995
- In Vivo Evaluation of a Pulsatile Impeller Total HeartAsaio Journal, 1994
- Multicenter clinical evaluation of the HeartMate 1000 IP left ventricular assist deviceThe Annals of Thoracic Surgery, 1992
- Heterotopic heart transplantation. A life-saving procedure with a size-mismatched donor.Japanese Circulation Journal, 1991
- Clinical Use of the Total Artificial HeartNew England Journal of Medicine, 1984
- Treatment of postoperative low output syndrome with intraaortic balloon pumping: Experience with 419 patientsThe American Journal of Cardiology, 1980
- Diastolic balloon pumping (with carbon dioxide) in the aorta—A mechanical assistance to the failing circulationAmerican Heart Journal, 1962