Segmental and dynamic intensity-modulated radiotherapy delivery techniques for micro-multileaf collimator
- 25 June 2003
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 30 (7) , 1758-1767
- https://doi.org/10.1118/1.1578791
Abstract
A leaf sequencing algorithm has been implemented to deliver segmental and dynamic multileaf collimated intensity-modulated radiotherapy (SMLC-IMRT and DMLC-IMRT, respectively) using a linear accelerator equipped with a micro-multileaf collimator (mMLC). The implementation extends a previously published algorithm for the SMLC-IMRT to include the dynamic MLC-IMRT method and several dosimetric considerations. The algorithm has been extended to account for the transmitted radiation and minimize the leakage between opposing and neighboring leaves. The underdosage problem associated with the tongue-and-groove design of the MLC is significantly reduced by synchronizing the MLC leaf movements. The workings of the leaf sequencing parameters have been investigated and the results of the planar dosimetric investigations show that the sequencing parameters affect the measured dose distributions as intended. Investigations of clinical cases suggest that SMLC and DMLC delivery methods produce comparable results with leaf sequences obtained by root-mean-square (RMS) errors specification of 1.5% and lower, approximately corresponding to 20 or more segments. For SMLC-IMRT, there is little to be gained by using an RMS error specification smaller than 2%, approximately corresponding to 15 segments; however, more segments directly translate to longer treatment time and more strain on the MLC. The implemented leaf synchronization method does not increase the required monitor units while it reduces the measured TG underdoses from a maximum of 12% to a maximum of 3% observed with single field measurements of representative clinical cases studied. (C) 2003 American Association of Physicists in Medicine.Keywords
This publication has 31 references indexed in Scilit:
- Patient specific quality assurance for the delivery of intensity modulated radiotherapyJournal of Applied Clinical Medical Physics, 2003
- Film dosimetry for intensity modulated radiation therapy: Dosimetric evaluationMedical Physics, 2002
- An optimized leaf-setting algorithm for beam intensity modulation using dynamic multileaf collimatorsPhysics in Medicine & Biology, 1998
- Two-dimensional film dosimetry application in heterogeneous materials exposed to megavoltage photon beamsMedical Physics, 1997
- Treatment delivery accuracy in intensity-modulated conformal radiotherapyPhysics in Medicine & Biology, 1995
- Dose calculation for photon beams with intensity modulation generated by dynamic jaw or multileaf collimationsMedical Physics, 1994
- X-ray field compensation with multileaf collimatorsInternational Journal of Radiation Oncology*Biology*Physics, 1994
- An analytical solution for the dynamic control of multileaf collimatorsPhysics in Medicine & Biology, 1994
- The role of local treatment in the cure of cancerEuropean Journal Of Cancer, 1992