Assessment of effective dose and dose to the lens of the eye for the interventional cardiologist
- 28 October 2008
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 132 (3) , 313-318
- https://doi.org/10.1093/rpd/ncn296
Abstract
This study investigates the relationship between personal dosemeter (PD) reading, effective dose and dose to the lens of the eye for interventional cardiologists in Norway. Doses were recorded with thermoluminescence dosemeters (TLD-100) for 14 cardiologists, and the effective doses were estimated using the Niklason algorithm. The procedures performed were coronary angiography and percutaneous coronary intervention, and all the hospitals (eight) in Norway, which are performing these procedures, were included in the study. Effective dose per unit dose–area product varied by a factor of 5, and effective dose relative to PD reading varied between 4 and 39%. Eye lens doses ranged from 39 to 138% of the dosemeter reading. On the basis of an estimated annual workload of 900 procedures, the annual effective doses ranged from 1 to 11 mSv. The estimated annual doses to the unprotected eye ranged from 9 to 210 mSv. According to the ICRP dose limits, the results indicate that the eye could be the limiting organ.Keywords
This publication has 20 references indexed in Scilit:
- Monte Carlo simulations of occupational radiation doses in interventional radiologyThe British Journal of Radiology, 2007
- Simultaneous determination of equivalent dose to organs and tissues of the patient and of the physician in interventional radiology using the Monte Carlo methodPhysics in Medicine & Biology, 2006
- Dosimetry of Occupationally Exposed Persons in Diagnostic and Interventional Arteriography. Part 2: Assessment of Effective DoseRadiation Protection Dosimetry, 1999
- Radiation exposure to medical staff in interventional and cardiac radiology.The British Journal of Radiology, 1998
- Lens injuries induced by occupational exposure in non-optimized interventional radiology laboratories.The British Journal of Radiology, 1998
- Radiation exposure to patients and operators during diagnostic catheterization and coronary angioplastyCatheterization and Cardiovascular Diagnosis, 1997
- Radiation Risk and Exposure of Radiologists and Patients during Coronary Angiography and Percutaneous Transluminal Coronary Angioplasty (PTCA)Radiation Protection Dosimetry, 1995
- The Estimation of Occupational Effective Dose in Diagnostic Radiology With Two DosimetersHealth Physics, 1994
- Exposure to Operating Staff During Cardiac Catheterisation Measured by Thermoluminescence DosimetryRadiation Protection Dosimetry, 1992
- The dependence of the scattered radiation dose to personnel on technique factors in diagnostic radiologyThe British Journal of Radiology, 1992