Hypothetical mortality risk associated with spiral computed tomography of the maxilla and mandible
- 1 October 1996
- journal article
- Published by Wiley in European Journal of Oral Sciences
- Vol. 104 (5-6) , 503-510
- https://doi.org/10.1111/j.1600-0722.1996.tb00133.x
Abstract
In the present study, dose measurements have been conducted following examination of the maxilla and mandible with spiral computed tomography (CT). The measurements were carried out with 2 phantoms, a head and neck phantom and a full body phantom. The analysis of applied thermoluminescent dosimeters yielded radiation doses for organs and tissues in the head and neck region between 0.6 and 16.7 mGy when 40 axial slices and 120 kV/165 mAs were used as exposure parameters. The effective dose was calculated as 0.58 and 0.48 mSv in the maxilla and mandible, respectively. Tested methods for dose reduction showed a significant decrease of radiation dose from 40 to 65%. Based on these results, the mortality risk was estimated according to calculation models recommended by the Committee on the Biological Effects of Ionizing Radiations and by the International Commission on Radiological Protection. Both models resulted in similar values. The mortality risk ranges from 46.2×10-6 for 20-year-old men to 11.2×10−6 for 65-year-old women. Using 2 methods of dose reduction, the mortality risk decreased by ∼ 50 to 60% to 19.1×10−6 for 20-year-old men and 5.5×10−6 for 65-year-old women. It can be concluded that a CT scan of the maxillofacial complex causes a considerable radiation dose when compared with conventional radiographic examinations. Therefore, a careful indication for this imaging technique and dose reduction methods should be considered in daily practice.Keywords
This publication has 14 references indexed in Scilit:
- Lateral ridge augmentation using autografts and barrier membranes: A clinical study with 40 partially edentulous patientsJournal of Oral and Maxillofacial Surgery, 1996
- Individual model fabrication in maxillofacial radiology.Dento maxillo facial radiology, 1995
- Effective dose and risk assessment from computed tomography of the maxillofacial complex.Dento maxillo facial radiology, 1995
- Absorbed doses from computed tomography for dental implant surgery: comparison with conventional tomography.Dento maxillo facial radiology, 1993
- Absorbed dose determination for tomographic implant site assessment techniquesOral Surgery, Oral Medicine, Oral Pathology, 1992
- Determination of absorbed dose to water with ionisation chambers calibrated in free air for medium-energy X-raysPhysics in Medicine & Biology, 1988
- Radiobiologic risk estimation from dental radiologyOral Surgery, Oral Medicine, Oral Pathology, 1988
- Evaluation of autologous cancellous bone grafting of mandibular discontinuity defects in dogs using a Dacron-urethane prosthesisJournal of Oral and Maxillofacial Surgery, 1987
- The LancetThe Lancet, 1974
- Salivary gland tumors in atomic bomb survivors, Hiroshima-Nagasaki, 1957 to 1970Published by American Medical Association (AMA) ,1972