Devices for Rapid Diagnosis of Malaria: Evaluation of Prototype Assays That Detect Plasmodium falciparum Histidine-Rich Protein 2 and a Plasmodium vivax -Specific Antigen
Open Access
- 1 June 2003
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 41 (6) , 2358-2366
- https://doi.org/10.1128/jcm.41.6.2358-2366.2003
Abstract
The Para Sight F test was developed as a pioneer industry effort in the large-scale, process-controlled production of a device for the rapid diagnosis of malaria. This device performed well in field settings but was limited to the detection of a single malaria species, Plasmodium falciparum. The Para Sight F+V assay advanced upon the Para Sight F test format by incorporating a monoclonal antibody directed against a proprietary Plasmodium vivax -specific antigen, in addition to the antibody directed against P. falciparum histidine-rich protein 2, which was used in the Para Sight F assay. The modified assay was developed to add the capability to detect P. falciparum and P. vivax in a single-test-strip format. The present study evaluated three distinct Para Sight F+V prototypes with samples from symptomatic patients in regions of Thailand and Peru where malaria is endemic. Over a 2-year enrollment period (1998 and 1999), a total of 4,894 patients consented to participation in the study. Compared with the results for duplicate microscopic examinations of Giemsa-stained blood smears as the reference diagnostic standard, each successive prototype showed substantial improvement in performance. The final Para Sight F+V prototype, evaluated in 1999, had an overall sensitivity for detection of asexual P. falciparum parasites of 98%. The sensitivity of the device was 100% for P. falciparum densities of >500 parasites/μl, with a sensitivity of 83% for parasite densities of ≤500/μl. The specificity for the exclusion of P. falciparum was 93%. For P. vivax , the overall sensitivity was 87% for the final 1999 prototype. The sensitivities calculated for different levels of P. vivax parasitemia were 99% for parasite densities of >5,000/μl, 92% for parasite densities of 1,001 to 5,000/μl, 94% for parasite densities of 501 to 1,000/μl, and 55% for parasite densities of 1 to 500/μl. The specificity for the exclusion of P. vivax was 87%. The areas under the receiver operating characteristic curves for the diagnostic performance of the assay for the detection of P. falciparum and P. vivax were 0.8907 and 0.8522, respectively. These findings indicate that assays for rapid diagnosis have the potential to enhance diagnostic capabilities in those instances in which skilled microscopy is not readily available.Keywords
This publication has 41 references indexed in Scilit:
- Malaria Rapid Diagnostic Devices: Performance Characteristics of the Para Sight F Device Determined in a Multisite Field StudyJournal of Clinical Microbiology, 2001
- Comparison of IsoCode STIX and FTA Gene Guard Collection Matrices as Whole-Blood Storage and Processing Devices for Diagnosis of Malaria by PCRJournal of Clinical Microbiology, 2001
- Reliability of malaria microscopy in epidemiological studies: results of quality controlTropical Medicine & International Health, 2000
- Malaria diagnosis by the polymerase chain reaction: a field study in southeastern VenezuelaTransactions of the Royal Society of Tropical Medicine and Hygiene, 1998
- High prevalence of Plasmodium malariae and Plasmodium ovale in malaria patients along the Thai‐Myanmar border, as revealed by acridine orange staining and PCR‐based diagnosesTropical Medicine & International Health, 1998
- Prevalence of malaria parasitemia and accuracy of microscopic diagnosis in Haiti, October 1995Revista Panamericana de Salud Pública, 1998
- Accuracy of routine laboratory diagnosis of malaria in the United Kingdom.Journal of Clinical Pathology, 1994
- Diagnosis of malaria by detection of Plasmodium falciparum HRP-2 antigen with a rapid dipstick antigen-capture assayThe Lancet, 1994
- A computer program for non-parametric receiver operating characteristic analysisComputer Methods and Programs in Biomedicine, 1993
- Malaria epidemiology and detectabilityTransactions of the Royal Society of Tropical Medicine and Hygiene, 1982