Nontriggered magnetic resonance velocity measurement of the time‐average of pulsatile velocity
- 1 May 1993
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 29 (5) , 648-655
- https://doi.org/10.1002/mrm.1910290511
Abstract
The feasibility of the determination of the time-average of pulsatile velocity obtained via a nontriggered magnetic resonance (MR) acquisition is studied. The advantage of this method, in comparison with a triggered acquisition, is a considerable reduction (≈15×) in acquisition time. However, pul-satility causes image artifacts, known as ghosts, and the Fourier transform technique required for the imaging procedure accomplishes time-averaging of the complex MR signal. Both effects can result in errors in the velocity determined. Calculations show that these errors depend on the velocity time function and the acquisition parameters. In vivo comparison of triggered and nontriggered MR velocity measurements in the femoral artery of volunteers (n = 7) shows larger statistical and systematic errors in the latter, which depend on the excitation angle. Therefore, this nontriggered average velocity measurement is only useful as a fast and rough estimation of the time-averaged velocity.Keywords
This publication has 15 references indexed in Scilit:
- On the nature and reduction of the displacement artifact in flow imagesMagnetic Resonance in Medicine, 1991
- Cardiac myosin-induced myocarditis as a model of postinfectious autoimmunityEuropean Heart Journal, 1991
- A numerical investigation of the dependence of NMR signal from pulsatile blood flow in CINE pulse sequencesMedical Physics, 1991
- The measurement of time-averaged flow by magnetic resonance imaging using continuous acquisition in the carotid arteries and its comparison with Doppler ultrasoundClinical Physics and Physiological Measurement, 1990
- Three‐dimensional phase contrast angiographyMagnetic Resonance in Medicine, 1989
- Magnetic resonance velocity mapping: clinical application of a new technique.Heart, 1987
- Blood Flow Imaging by Cine Magnetic ResonanceJournal of Computer Assisted Tomography, 1986
- Reducing motion artifacts in two-dimensional Fourier transform imagingMagnetic Resonance Imaging, 1986
- Blood flow effects in magnetic resonance imagingAmerican Journal of Roentgenology, 1984
- A review of normal tissue hydrogen NMR relaxation times and relaxation mechanisms from 1–100 MHz: Dependence on tissue type, NMR frequency, temperature, species, excision, and ageMedical Physics, 1984