Lung Recruitment and Breathing Pattern During Variable Versus Continuous Flow Nasal Continuous Positive Airway Pressure in Premature Infants: An Evaluation of Three Devices
- 1 February 2001
- journal article
- clinical trial
- Published by American Academy of Pediatrics (AAP) in Pediatrics
- Vol. 107 (2) , 304-308
- https://doi.org/10.1542/peds.107.2.304
Abstract
Objective. To determine whether lung volume changes and breathing pattern parameters differ among 3 devices for delivery of nasal continuous positive airway pressure (CPAP) in premature infants. Methods. Thirty-two premature infants receiving nasal CPAP for apnea or mild respiratory distress were enrolled. Birth weight was (mean ± standard deviation) 1081 ± 316 g, gestational age 29 ± 2 weeks, age at study 13 ± 12 days, and fraction of inspired oxygen (Fio2) at study .29 ± .1. Three devices, applied in random order, were studied in each infant: continuous flow nasal CPAP via CPAP prongs, continuous flow nasal CPAP via modified nasal cannula, and variable flow nasal CPAP. After lung recruitment to standardize volume history, changes in lung volume (ΔVL) were assessed at nasal CPAP of 8, 6, 4, and 0 cm H2O using calibrated direct current-coupled respiratory inductance plethysmography. Results. ΔVL was significantly greater overall with the variable flow device compared with both the nasal cannula and CPAP prongs. However, ΔVL was not different between the cannula and the prongs. Respiratory rate, tidal volume, thoraco-abdominal asynchrony, and Fio2 were greater with the modified cannula than for either of the other 2 devices. Conclusion. Compared with 2 continuous flow devices, the variable flow nasal CPAP device leads to greater lung recruitment. Although a nasal cannula is able to recruit lung volume, it does so at the cost of increased respiratory effort and Fio2.Keywords
This publication has 12 references indexed in Scilit:
- Infant Flow Driver or single prong nasal continuous positive airway pressure: short-term physiological effectsActa Paediatrica, 1998
- Decreased imposed work with a new nasal continuous positive airway pressure devicePediatric Pulmonology, 1996
- Comparison of respiratory inductance plethysmography with thoracoabdominal compression in bronchial challenges in infants and young children.American Journal of Respiratory and Critical Care Medicine, 1996
- Nasal continuous positive airway pressure: experiences with a new technical approachActa Paediatrica, 1993
- Effect of nasal CPAP on thoracoabdominal motion in neonates with respiratory insufficiencyPediatric Pulmonology, 1991
- A new device for administration of nasal continuous positive airway pressure in the newbornCritical Care Medicine, 1988
- Measurement of Tidal Volume during High Frequency Ventilation by Impedance PlethysmographyPediatric Research, 1988
- Effects of Continuous Positive Airway Pressure on Pulmonary Function and Blood Gases of Infants with Respiratory Distress SyndromePediatric Research, 1978
- Positive End Expiratory Pressure: Effects on Lung Mechanics of Premature LambsNeonatology, 1978
- Treatment of the Idiopathic Respiratory-Distress Syndrome with Continuous Positive Airway PressureNew England Journal of Medicine, 1971