Shutter‐speed analysis of contrast reagent bolus‐tracking data: Preliminary observations in benign and malignant breast disease
Open Access
- 18 February 2005
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 53 (3) , 724-729
- https://doi.org/10.1002/mrm.20405
Abstract
The standard pharmacokinetic model applied to contrast reagent (CR) bolus-tracking (B-T) MRI (dynamic-contrast-enhanced) data makes the intrinsic assumption that equilibrium transcytolemmal water molecule exchange is effectively infinitely fast. Theory and simulation have suggested that this assumption can lead to significant errors. Recent analyses of animal model experimental data have confirmed two predicted signature inadequacies: a specific temporal mismatch with the B-T time-course and a CR dose-dependent underestimation of model parameters. The most parsimonious adjustment to account for this aspect leads to the “shutter-speed” pharmacokinetic model. Application of the latter to the animal model data mostly eliminates the two signature inadequacies. Here, the standard and shutter-speed models are applied to B-T data obtained from routine human breast examinations. The signature standard model temporal mismatch is found for each of the three invasive ductal carcinoma (IDC) cases and for each of the three fibroadenoma (FA) cases studied. It is effectively eliminated by use of the shutter-speed model. The size of the mismatch is considerably greater for the IDC lesions than for the FA lesions, causing the shutter-speed model to exhibit improved discrimination of malignant IDC tumors from the benign FA lesions compared with the standard model. Furthermore, the shutter-speed model clearly reveals focal “hot spots” of elevated CR perfusion/permeation present in only the malignant tumors. Magn Reson Med 53:724–729, 2005.Keywords
This publication has 18 references indexed in Scilit:
- Evidence for shutter-speed variation in CR bolus-tracking studies of human pathologyNMR in Biomedicine, 2004
- Intracellular manganese ions provide strong T1 relaxation in rat myocardiumMagnetic Resonance in Medicine, 2004
- Microcirculation and microvasculature in breast tumors: Pharmacokinetic analysis of dynamic MR image seriesMagnetic Resonance in Medicine, 2004
- Simultaneous measurement of arterial input function and tumor pharmacokinetics in mice by dynamic contrast enhanced imaging: Effects of transcytolemmal water exchangeMagnetic Resonance in Medicine, 2004
- Modeling 1H exchange: An estimate of the error introduced in MRI by assuming the fast exchange limit in bolus trackingMagnetic Resonance in Medicine, 2004
- New model for analysis of dynamic contrast‐enhanced MRI data distinguishes metastatic from nonmetastatic transplanted rodent prostate tumorsMagnetic Resonance in Medicine, 2004
- Variation of the relaxographic “shutter‐speed” for transcytolemmal water exchange affects the CR bolus‐tracking curve shapeMagnetic Resonance in Medicine, 2003
- Diffusion in compartmental systems. II. Diffusion‐weighted measurements of rat brain tissue in vivo and postmortem at very large b‐valuesMagnetic Resonance in Medicine, 2003
- Equilibrium water exchange between the intra‐ and extracellular spaces of mammalian brainMagnetic Resonance in Medicine, 2003
- Critical role of spatial resolution in dynamic contrast‐enhanced breast MRIJournal of Magnetic Resonance Imaging, 2001