MALDI-MS imaging of features smaller than the size of the laser beam
Top Cited Papers
- 1 October 2005
- journal article
- Published by American Chemical Society (ACS)
- Vol. 16 (10) , 1654-1659
- https://doi.org/10.1016/j.jasms.2005.06.006
Abstract
The feasibility of matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) imaging of features smaller than the laser beam size has been demonstrated. The method involves the complete ablation of the MALDI matrix coating the sample at each sample position and moving the sample target a distance less than the diameter of the laser beam before repeating the process. In the limit of complete sample ablation, acquiring signal from adjacent positions spaced by distances smaller than the sample probe enhances image resolution as the measured analyte signal only arises from the overlap of the laser beam size and the non-ablated sample surface. Image acquisition of features smaller than the laser beam size has been demonstrated with peptide standards deposited on electron microscopy calibration grids and with neuropeptides originating from single cells. The presented MS imaging technique enables ∼25 µm imaging spatial resolution using commercial MALDI mass spectrometers having irregular laser beam sizes of several hundred micron diameters. With appropriate sampling, the size of the laser beam is not a strict barrier to the attainable MALDI-MS imaging resolution.Keywords
This publication has 21 references indexed in Scilit:
- Direct analysis of drug candidates in tissue by matrix‐assisted laser desorption/ionization mass spectrometryJournal of Mass Spectrometry, 2003
- Proteomic patterns of tumour subsets in non-small-cell lung cancerThe Lancet, 2003
- Direct tissue analysis using matrix‐assisted laser desorption/ionization mass spectrometry: practical aspects of sample preparationJournal of Mass Spectrometry, 2003
- Matrix-assisted ultraviolet laser desorption of non-volatile compoundsPublished by Elsevier ,2001
- Imaging mass spectrometry: A new technology for the analysis of protein expression in mammalian tissuesNature Medicine, 2001
- Combining solid-phase preconcentration, capillary electrophoresis and off-line matrix-assisted laser desorption/ionization mass spectrometry: intracerebral metabolic processing of peptide Ein vivoJournal of Mass Spectrometry, 1999
- Molecular Imaging of Biological Samples: Localization of Peptides and Proteins Using MALDI-TOF MSAnalytical Chemistry, 1997
- Imaging of thin-layer chromatograms using matrix-assisted laser desorption/ionization mass spectrometryAnalytical Chemistry, 1995
- Laser Desorption/Ionization Mass Spectrometry of Proteins of Mass 100 000 to 250 000 DaltonAngewandte Chemie International Edition in English, 1989
- Electrospray ion source. Another variation on the free-jet themeThe Journal of Physical Chemistry, 1984