High temporal and spatial resolution studies of bone cells using real‐time confocal reflection microscopy
- 1 September 1994
- Vol. 16 (5) , 285-294
- https://doi.org/10.1002/sca.4950160506
Abstract
Chick and rat bone-derived cells were mounted in sealed coverslip-covered chambers; individual osteoclasts (but also osteoblasts) were selected and studied at 37°C using three different types of high-speed scanning confocal microscopes: (1) A Noran Tandem Scanning Microscope (TSM) was used with a low light level, cooled CCD camera for image transfer to a Noran TN8502 frame store-based image analysing computer to make time lapse movie sequences using 0.1 s exposure periods, thus losing some of the advantage of the high frame rate of the TSM. Rapid focus adjustment using computer controlled piezo drivers permitted two or more focus planes to be imaged sequentially: thus (with additional light-source shuttering) the reflection confocal image could be alternated with the phase contrast image at a different focus. Individual cells were followed for up to 5 days, suggesting no significant irradiation problem. (2) Exceptional temporal and spatial resolution is available in video rate laser confocal scanning microscopes (VRCSLMs). We used the Noran Odyssey unitary beam VRCSLM with an argon ion laser at 488 nm and acousto-optic deflection (AOD) on the line axis: this instrument is truly and adjustably confocal in the reflection mode. (3) We also used the Lasertec 1LM11 line scan instrument, with an He-Ne laser at 633 nm, and AOD for the frame scan. We discuss the technical problems and merits of the different approaches. The VRCSLMs documented rapid, real-time oscillatory motion: all the methods used show rapid net movement of organelles within bone cells. The interference reflection mode gives particularly strong contrasts in confocal instruments. Phase contrast and other interference methods used in the microscopy of living cells can be used simultaneously in the TSM.Keywords
This publication has 26 references indexed in Scilit:
- Video-rate confocal reflection microscopy of neoplastic cells: Rate of intracellular movement and peripheral motility characteristic of neoplastic cell line (RSK4) with high degree of growth independence in vitroScanning, 1993
- Vitronectin receptor has a role in bone resorption but does not mediate tight sealing zone attachment of osteoclasts to the bone surface.The Journal of cell biology, 1991
- Kinetics of the osteoclast cytoskeleton during the resorption cycle in vitroJournal of Bone and Mineral Research, 1991
- Immunocytochemical distribution of extracellular matrix receptors in human osteoclasts: A β3 integrin is colocalized with vinculin and talin in the podosomes of osteoclastoma giant cellsExperimental Cell Research, 1989
- Combining confocal and conventional modes in tandem scanning reflected light microscopyScanning, 1989
- Microcinematographic and autoradiographic kinetic studies of bone cell differentiation in vitro: Matrix formation and mineralizationBone, 1989
- Adhesion patterns and cytoskeleton of rabbit osteoclasts on bone slices and glassJournal of Bone and Mineral Research, 1988
- Alpha-actinin-containing aggregates in transformed cells are highly dynamic structures.The Journal of cell biology, 1987
- Cell-substratum interaction of cultured avian osteoclasts is mediated by specific adhesion structures.The Journal of cell biology, 1984
- Organization of pp60src and selected cytoskeletal proteins within adhesion plaques and junctions of Rous sarcoma virus-transformed rat cells.The Journal of cell biology, 1981