Initial and 6-Month Results of Biodegradable Poly- l -Lactic Acid Coronary Stents in Humans
Top Cited Papers
- 25 July 2000
- journal article
- other
- Published by Wolters Kluwer Health in Circulation
- Vol. 102 (4) , 399-404
- https://doi.org/10.1161/01.cir.102.4.399
Abstract
Background —Although metallic stents are effective in preventing acute occlusion and reducing late restenosis after coronary angioplasty, many concerns still remain. Compared with metallic stents, poly- l -lactic acid (PLLA) stents are biodegradable and can deliver drugs locally. The aim of this study was to evaluate the feasibility, safety, and efficacy of the PLLA stent. Methods and Results —Fifteen patients electively underwent PLLA Igaki-Tamai stent implantation for coronary artery stenoses. The Igaki-Tamai stent is made of a PLLA monopolymer, has a thickness of 0.17 mm, and has a zigzag helical coil pattern. A balloon-expandable covered sheath system was used, and the stent expanded by itself to its original size with an adequate temperature. A total of 25 stents were successfully implanted in 19 lesions in 15 patients, and angiographic success was achieved in all procedures. No stent thrombosis and no major cardiac event occurred within 30 days. Coronary angiography and intravascular ultrasound were serially performed 1 day, 3 months, and 6 months after the procedure. Angiographically, both the restenosis rate and target lesion revascularization rate per lesion were 10.5%; the rates per patient were 6.7% at 6 months. Intravascular ultrasound findings revealed no significant stent recoil at 1 day, and they revealed stent expansion at follow-up. No major cardiac event, except for repeat angioplasty, developed within 6 months. Conclusions —Our preliminary experience suggests that coronary PLLA biodegradable stents are feasible, safe, and effective in humans. Long-term follow-up with more patients will be required to validate the long-term efficacy of PLLA stents.Keywords
This publication has 15 references indexed in Scilit:
- A Biodegradable Poly-l-lactic Acid Coronary Stent in the Porcine Coronary ArteryJournal of Interventional Cardiology, 1999
- Sustained Local Delivery of Dexamethasone by a Novel Intravascular Eluting Stent to Prevent Restenosis in the Porcine Coronary Injury ModelJournal of the American College of Cardiology, 1997
- Three-Year Follow-up after Implantation of Metallic Coronary-Artery StentsNew England Journal of Medicine, 1996
- Restenosis after percutaneous transluminal coronary angioplasty: Have we been aiming at the wrong target?Journal of the American College of Cardiology, 1995
- Biological response of intramedullary bone to poly‐L‐lactic acidJournal of Applied Biomaterials, 1993
- Coronary intimal proliferation after balloon injury and stenting in swing: An animal model of restenosisJournal of the American College of Cardiology, 1992
- Enzymatic activity toward poly(L‐lactic acid) implantsJournal of Biomedical Materials Research, 1990
- Biodegradable hollow fibres for the controlled release of drugsBiomaterials, 1988
- Resorbable poly(L-lactide) plates and screws for the fixation of zygomatic fracturesJournal of Oral and Maxillofacial Surgery, 1987
- Intravascular Stents to Prevent Occlusion and Re-Stenosis after Transluminal AngioplastyNew England Journal of Medicine, 1987