Latex-Coated Polymeric Monolithic Ion-Exchange Stationary Phases. 2. Micro-Ion Chromatography
- 7 December 2004
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (2) , 417-423
- https://doi.org/10.1021/ac048747l
Abstract
Latex-coated monolithic polymeric stationary phases are used for micro-ion chromatography (μ-IC) of inorganic anions. Monolithic columns were prepared by the in situ polymerization of butyl methacrylate, ethylene dimethacrylate, and 2-acrylamido-2-methyl-1-propanesulfonic acid within fused-silica capillaries of varying internal diameters. Introduction of ion-exchange sites was achieved by coating the anionic polymeric monolith with either Dionex AS10 or Dionex AS18 quaternary ammonium functionalized latex particles to give total ion-exchange capacities in the range 9−24 nequiv for a 30-cm column. The resultant μ-IC columns were used for the separation of anionic analytes using chloride or acetate as the eluent-competing ion and direct UV spectrophotometric detection at 195 nm or using hydroxide as the eluent-competing ion and suppressed or nonsuppressed contactless conductivity detection. Separation efficiencies of 13 000 plates/m were observed (for iodate), and separation efficiency was maintained for large increases in flow rate (up to 42 μL/min, corresponding to a linear flow velocity of 18.5 mm/s), enabling highly reproducible, rapid separations to be achieved (seven analyte anions in less than 2 min). Use of a hollow fiber micromembrane suppressor enabled effective suppression of hydroxide eluents over the range 0.5−5.0 mM, thereby permitting suppressed conductivity detection to be performed. However, the relatively large size of the suppressor resulted in reduced separation efficiencies (e.g., 5400 plates/m for iodate). Detection limits obtained with suppressed conductivity detection were in the range 0.4−1.2 μM.Keywords
This publication has 30 references indexed in Scilit:
- New Products: New ProductsAnalytical Chemistry, 2004
- Investigation of conditions allowing the synthesis of acrylamide‐based monolithic microcolumns for capillary electrochromatography and of factors determining the retention of aromatic compounds on these stationary phasesElectrophoresis, 2003
- Coupling of monolithic columns with sequential injection techniqueAnalytica Chimica Acta, 2003
- Miniaturized movable contactless conductivity detection cell for capillary electrophoresisElectrophoresis, 2003
- Determination of the purity of phenoxymethylpenicillin by micellar electrokinetic chromatography and reversed phase liquid chromatography on a monolithic silica columnJournal of Separation Science, 2003
- Separation of selected humic degradation compounds by capillary electrochromatography with monolithic and packed columnsElectrophoresis, 2003
- Towards a microchip-based chromatographic platform. Part 1: Evaluation of sol-gel phases for capillary electrochromatographyElectrophoresis, 2002
- A New Class of Continuous Polymer Supports Prepared by Ring-Opening Metathesis Polymerization: A Straightforward Route to Functionalized MonolithsMacromolecules, 2000
- Performance of a Monolithic Silica Column in a Capillary under Pressure-Driven and Electrodriven ConditionsAnalytical Chemistry, 2000
- Capillary Ion Chromatography with On-Line High-Pressure Electrodialytic NaOH Eluent Production and Gradient GenerationAnalytical Chemistry, 1997