Tissue compatibility of different intracranial implant materials: In-vivo and in-vitro studies
- 1 March 1984
- journal article
- research article
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 72 (1-2) , 45-59
- https://doi.org/10.1007/bf01406813
Abstract
Tissue compatibility of different intracranial implant materials was studied by a tissue culture method using fibroblasts. The same materials were implanted in the crania of rabbits for two months. Undecalcified sections of rabbit crania, including the materials, were stained with Fuchsin and Methylene Blue and Masson-Goldner methods. Soft X-ray was used to detect new bone formation. The materials used were alumina ceramics, hydroxy apatite ceramics, titanium, methylmethacrylate, Sugita aneurysm clip, silicon shunt tube and lyophilized human dura mater (Lyo-dura). Both alumina ceramics and hydroxy apatite ceramics showed an excellent tissue compatibility in-vivo experiments. Although alumina ceramics showed an excellent tissue compatibility in in-vitro experiments, hydroxy apatite ceramics showed less compatibility. Methylmethacrylate prepared one week before the experiment showed excellent compatibility, but the same material prepared at the time of experiment showed only fair compatibility. The titanium and silicon shunt tube showed excellent compatibility. The Sugita aneurysm clip, made from elgiloy, showed fair compatibility, while Lyo-dura showed excellent compatibility in in-vitro experiments, but less compatibility in in-vivo experiments. The reasons for the differences between the results of in-vivo and in-vitro experiments are discussed.This publication has 35 references indexed in Scilit:
- A fast, simple, and satisfactory method of cranioplastySurgical Neurology, 1981
- Reconstruction of the sellar floor during transsphenoidal operations using alumina ceramicSurgical Neurology, 1981
- Tissue Reactin to Methyl Methacrylate Monomer:A Comparative Study in the Rabbit's Ear on the Toxicity of Methyl Methacrylate Monomer of Varying CompositionActa Orthopaedica, 1976
- Electron Microscopic Study of the Cytotoxicity of Cadmium and Mercury In VitroJournal of Dental Research, 1975
- The role of porous polymeric materials in prosthesis attachmentJournal of Biomedical Materials Research, 1974
- Mechanical properties of the bone-porous biomaterial interface: Elastic behaviorJournal of Biomedical Materials Research, 1973
- Structural Strength of the Interface Between Bone and Nondegradable Porous Ceramic ImplantsJournal of Dental Research, 1973
- ULTRASTRUCTURE OF CELL ATTACHMENT TO SUBSTRATUM IN VITROThe Journal of cell biology, 1968
- Cobalt as a CarcinogenNature, 1954
- Cranioplasty with Acrylic PlatesJournal of Neurosurgery, 1946