Determination of Polybrominated Diphenyl Ethers and Polychlorinated Biphenyls in Human Adipose Tissue by Large-Volume Injection−Narrow-Bore Capillary Gas Chromatography/Electron Impact Low-Resolution Mass Spectrometry
- 18 January 2002
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 74 (4) , 790-798
- https://doi.org/10.1021/ac010784e
Abstract
A new analytical method has been developed for the quantification of polybrominated diphenyl ethers (PBDEs) in human adipose tissue samples. After Soxhlet extraction and a cleanup procedure using two successive solid-phase extraction cartridges containing acid silica and acid silica:neutral silica:deactivated basic alumina (from top to bottom), detection can been achieved by narrow-bore (0.10-mm i.d.) capillary gas chromatography/electron impact low-resolution mass spectrometry using a large-volume injection technique. Using narrow-bore capillaries, it is possible to analyze complex mixtures in a short time (up to 10 min), saving 50% or more of the analysis time of conventional columns while maintaining a similar resolution power. The method allows the determination of five major PBDE congeners (BDE 28, 47, 99, 100, and 153) at concentrations below 1 ng/g lipid weight. Detection limits in the selected ion mode varied between 0.05 and 0.30 ng/g lipid weight, depending on the degree of bromination. The sensitivity of this method can compete with low-resolution mass spectrometry with electron capture ionization, while a much better selectivity is obtained. Levels of PBDEs in 20 Belgian human adipose tissue samples ranged between 2.18 and 11.70 ng/g lipid weight and were similar to previously reported values from Europe.Keywords
This publication has 10 references indexed in Scilit:
- Mass spectrometric detection in narrow-bore (0.10 mm I.D.) capillary chromatography: Fast, sensitive and selective analysis of polychlorinated biphenylsJournal of Chromatography A, 2001
- Simplified method for determination of organochlorine pollutants in human serum by solid-phase disk extraction and gas chromatographyChemosphere, 2001
- Comparative Study on Total Lipid Determination using Soxhlet, Roese-Gottlieb, Bligh & Dyer, and Modified Bligh & Dyer Extraction MethodsJournal of Food Composition and Analysis, 2001
- Microwave-assisted extraction or saponification combined with microwave-assisted decomposition applied in pretreatment of soil or mussel samples for the determination of polychlorinated biphenylsAnalytica Chimica Acta, 2000
- Certain organochlorine and organobromine contaminants in Swedish human milk in perspective of past 20–30 yearsChemosphere, 2000
- Polybrominated Biphenyls and DiphenylethersPublished by Springer Nature ,2000
- Polybrominated diphenyl ethers detected in human adipose tissue from SpainChemosphere, 1999
- Gas chromatographic identification and quantification of polybrominated diphenyl ethers in a commercial product, Bromkal 70-5DEJournal of Chromatography A, 1998
- A collaborative study of 209 PCB congeners and 6 Aroclors on 20 different HRGC columns 2. Semi-quantitative Aroclor congener distributionsAnalytical and Bioanalytical Chemistry, 1997
- Polybrominated diphenyl ethers (PBDE) in biological samples from the Swedish environmentChemosphere, 1993