In Vivo Experimental Testing of a Microaxial Blood Pump for Right Ventricular Support
- 1 February 2006
- journal article
- Published by Wiley in Artificial Organs
- Vol. 30 (2) , 94-100
- https://doi.org/10.1111/j.1525-1594.2006.00187.x
Abstract
The incidence of isolated right ventricular (RV) failure is rare in postcardiotomy patients, but high in patients undergoing implantation of a left ventricular assist device or cardiac transplantation. Therefore, we have developed a new microaxial flow device and report on our first in vivo animal trials. Six healthy adult female sheep weighing 80-90 kg underwent implantation of the microaxial blood pump for partial unloading of the right ventricle. This pump is a miniaturized rotary blood pump with a diameter of only 6.4 mm and a weight of 11 g. The inner volume of the pump is limited to 12 mL, and the inner artificial blood contacting surface is 65 cm(2). The pump consists of a rotor driven by an incorporated brushless direct current motor, the housing of the rotor, the inflow cage, the outflow cannula, and the driveline. At the maximum speed of 32,500 rotations/min, a flow of 6 L/min can be delivered. The inflow and outflow conduit were anastomosed to the right atrium and the main pulmonary artery, respectively. Hemodynamic and echocardiographic data as well as blood samples were measured over the whole test period of 7 days. The hearts and lungs as well as the pump were explanted for a thorough examination at the end of the trial. Systemic arterial blood pressures remained unchanged during the entire test period. RV cardiac output was diminished significantly as demonstrated by the echocardiographic studies. The number of platelets decreased perioperatively, but recovered within the test period. The free hemoglobin was not enhanced postoperatively indicating no significant hemolysis. Liver function was only slightly impaired due to operative reasons (increase in bilirubin on the first postoperative day but normalization within the test period). The pathologic examination revealed some clots at the inflow cage and fibrin depositions on the impeller as well as on the inner surface of the outflow graft without an impairment of pump function. Our results demonstrate that this newly developed microaxial blood pump is a promising device for RV support, but it cannot be driven without any anticoagulation.Keywords
This publication has 16 references indexed in Scilit:
- Scoring system determines successful RVAD explant following BiVAD support: implications for destination therapyThe Journal of Heart and Lung Transplantation, 2003
- Mechanical support for isolated RV failure in post-cardiotomy patientsThe Journal of Heart and Lung Transplantation, 2003
- Successful use of a miniaturized bypass system with the DeltaStream extracorporeal rotary blood pumpThe Journal of Thoracic and Cardiovascular Surgery, 2003
- WhenShould We Consider Right Ventricular Support?The Thoracic and Cardiovascular Surgeon, 2002
- Bi-Ventricular Axial Micro- Pump: Impact on Blood Cell IntegritySwiss Surgery, 2001
- From a Lab Type to a Product: A Retrospective View on Impella's Assist TechnologyArtificial Organs, 2001
- Current strategy of temporary circulatory support for severe cardiac failure after operationThe Annals of Thoracic Surgery, 1999
- Experience with right ventricular assist devices for perioperative right-sided circulatory failureThe Annals of Thoracic Surgery, 1996
- Complications of extracorporeal life support systems using heparin-bound surfaces: The risk of intracardiac clot formationThe Journal of Thoracic and Cardiovascular Surgery, 1995
- Mechanical ventricular assistance for the failing right ventricle after cardiac transplantationEuropean Journal of Cardio-Thoracic Surgery, 1995