Comparison of bone ingrowth into cobalt chrome sphere and titanium fiber mesh porous coated cementless canine acetabular components
- 1 May 1993
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 27 (5) , 639-644
- https://doi.org/10.1002/jbm.820270511
Abstract
Bone ingrowth into uncemented hemispherical canine acetabular components porous‐coated with cobalt chrome spheres was compared to those porous‐coated with titanium fiber mesh. While good bone ingrowth was noted in both types of porous coatings at 6 weeks after surgery with no difference in the histologic quality of the ingrown bone, quantitation of bone ingrowth showed that significantly more bone grew into titanium fiber mesh porous‐coated components. The mean amount of bone ingrowth measured 10.5% of the area of the porous coating with fiber mesh coatings and only 5.5% of the area of the porous coating with spherical coatings (significant difference at P < .0005). The mean area density of the ingrown bone inside the pores measured 21.5% of the pore area with fiber mesh coatings, also significantly greater than 13.4% of the pore area with sphere coatings (P < .025). The ingrown bone penetrated a mean 66% of the depth of the porous layer with fiber mesh coatings compared to 32% of the depth of the porous layer with spherical coating (significant difference at P < .0005). The mean extent of the periphery of the porous layer with bone ingrowth was 88% for the mesh coatings and 55% for the spherical coatings (also a significant difference at P < .01). © 1993 John Wiley & Sons, Inc.Keywords
This publication has 15 references indexed in Scilit:
- A Double-Blind Study on the Effects of a Capacitively Coupled Electrical Field on Bone Ingrowth Into Porous-Surfaced Canine Total Hip ProsthesesClinical Orthopaedics and Related Research, 1990
- Loosening of Cobalt Chrome Beads from a Porous-Coated Acetabular ComponentPublished by Wolters Kluwer Health ,1988
- Comparison of Measurement Methods for Characterization of Porous CoatingsPublished by ASTM International ,1987
- A comparative study of porous coatings in a weight-bearing total hip-arthroplasty model.Journal of Bone and Joint Surgery, 1986
- Radiographic and Morphologic Studies of Load-Bearing Porous-Surfaced Structured ImplantsClinical Orthopaedics and Related Research, 1981
- The Optimum Pore Size for the Fixation of Porous-Surfaced Metal Implants by the Ingrowth of BoneClinical Orthopaedics and Related Research, 1980
- Factors governing the mechanical behavior of the implant-porous coating-trabecular bone interfaceJournal of Biomechanics, 1978
- An evaluation of bone growth into porous high density polyethyleneJournal of Biomedical Materials Research, 1976
- Attachment of prostheses to the musculo‐skeletal system by tissue ingrowth and mechanical interlockingJournal of Biomedical Materials Research, 1973
- Sintered Fiber Metal Composites as a Basis for Attachment of Implants to BoneJournal of Bone and Joint Surgery, 1971