AAPM/RSNA Physics Tutorial for Residents: Topics in CT
- 1 September 2002
- journal article
- review article
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 22 (5) , 1255-1268
- https://doi.org/10.1148/radiographics.22.5.g02se041255
Abstract
Several image-processing methods for computed tomographic (CT) examinations are currently being used in clinical radiology departments. Image processing involves operations such as reformatting of original CT images, volume-rendered displays, surface-rendered displays, and physiologic imaging analysis. The reformatting process does not alter the CT voxels in any way; instead it uses them in off-axis views and displays the images produced from the original reconstruction process in an orientation other than how they were originally generated. Sagittal, coronal, oblique, and curved reformatting are standard reformatting methods. Other reformatting techniques include maximum-intensity projection, minimum-intensity projection, and variable thickness viewing. Volume and surface rendering are two different methods for reformatting axial images into three-dimensional views. CT perfusion allows the measurement of physiologic parameters over time. Additional postprocessing efforts can potentially add value to the patients and their outcomes, as can be seen in the cases that illustrate this article.Keywords
This publication has 16 references indexed in Scilit:
- CT AngiographyAmerican Journal of Roentgenology, 2001
- Two-Dimensional Multiplanar and Three-Dimensional Volume-Rendered Vascular CT in Pancreatic CarcinomaAmerican Journal of Roentgenology, 2001
- Three-dimensional spiral CT cholangiography with minimum intensity projection in patients with suspected obstructive biliary disease: comparison with percutaneous transhepatic cholangiographyAbdominal Radiology, 2001
- Preoperative Use of 3D Volume Rendering to Demonstrate Renal Tumors and Renal AnatomyRadioGraphics, 2000
- Helical CT Cholangiography with Three-Dimensional Volume Rendering Using an Oral Biliary Contrast AgentAmerican Journal of Roentgenology, 2000
- CT angiography with volume rendering for quantifying vascular stenoses: in vitro validation of accuracy.American Journal of Roentgenology, 1999
- Renal Artery Stenosis: CT Angiography—Comparison of Real-time Volume-rendering and Maximum Intensity Projection AlgorithmsRadiology, 1999
- Pancreaticoduodenal arcades and dorsal pancreatic artery: comparison of CT angiography with three-dimensional volume rendering, maximum intensity projection, and shaded-surface display.American Journal of Roentgenology, 1999
- Multiplanar CT pancreatography and distal cholangiography with minimum intensity projections.Radiology, 1998
- Measuring carotid artery stenosis using CT angiography: the dilemma of artifactual lumen eccentricity.American Journal of Roentgenology, 1998