Clinical Evaluation of a Computer-controlled Pressure Support Mode
- 1 April 2000
- journal article
- clinical trial
- Published by American Thoracic Society in American Journal of Respiratory and Critical Care Medicine
- Vol. 161 (4) , 1161-1166
- https://doi.org/10.1164/ajrccm.161.4.9904064
Abstract
We have designed a computerized system providing closed-loop control of the level of pressure support ventilation (PSV). The system sets itself at the lowest level of PSV that maintains respiratory rate (RR), tidal volume (Vt), and end-tidal CO2 pressure (Pet CO2 ) within predetermined ranges defining acceptable ventilation (i.e., 12 < RR < 28 cycles/min, Vt > 300 ml [ > 250 if weight < 55 kg], and Pet CO2 < 55 mm Hg [ < 65 mm Hg if chronic CO2 retention]). Ten patients received computer-controlled (automatic) PSV and physician-controlled (standard) PSV, in random order, during 24 h for each mode. An estimation of occlusion pressure (P0.1) was recorded continuously. The average time spent with acceptable ventilation as previously defined was 66 ± 24% of the total ventilation time with standard PSV versus 93 ± 8% with automatic PSV (p < 0.05), whereas the level of PSV was similar during the two periods (17 ± 4 cm H2O versus 19 ± 6 cm H2O). The time spent with an estimated P0.1 above 4 cm H2O was 34 ± 35% of the standard PSV time versus only 11 ± 17% of the automatic PSV time (p < 0.01). Automatic PSV increased the time spent within desired ventilation parameter ranges and apparently reduced periods of excessive workload.Keywords
This publication has 26 references indexed in Scilit:
- Occlusion pressure as a measure of respiratory center output cm conscious manPublished by Elsevier ,2003
- NéoGanesh: a working system for the automated control of assisted ventilation in ICUsArtificial Intelligence in Medicine, 1997
- Utilizing temporal data abstraction for data validation and therapy planning for artificially ventilated newborn infantsArtificial Intelligence in Medicine, 1996
- Closed-loop control of airway occlusion pressure at 0.1 second (P sub 0.1) applied to pressure-support ventilationCritical Care Medicine, 1996
- P0.1 is a useful parameter in setting the level of pressure support ventilationIntensive Care Medicine, 1995
- An adaptive lung ventilation controllerIEEE Transactions on Biomedical Engineering, 1994
- A knowledge-based system for assisted ventilation of patients in intensive care unitsJournal of Clinical Monitoring and Computing, 1992
- Early prediction of successful weaning during pressure support ventilation in chronic obstructive pulmonary disease patientsCritical Care Medicine, 1992
- P0.1/PIMax: An index for assessing respiratory capacity in acute respiratory failureIntensive Care Medicine, 1990
- A simplified acute physiology score for ICU patientsCritical Care Medicine, 1984