Histological changes in the aortic valve after balloon dilatation: evidence for a delayed healing process.
Open Access
- 1 June 1992
- Vol. 67 (6) , 445-449
- https://doi.org/10.1136/hrt.67.6.445
Abstract
OBJECTIVE--To investigate whether balloon dilatation of the aortic valve induces long-term macroscopic or histological changes or both to explain the restenosis process. DESIGN--Prospective study of 39 consecutive patients. Sixteen later (mean (SD) 12 (10) months) required operation. This non-randomised subgroup was compared with 10 patients who had aortic valve replacement without prior dilatation. SETTING--University cardiology and cardiac surgery centre and pathology department. PATIENTS--16 patients who had aortic valve replacement because of failure of or restenosis after balloon dilatation of the aortic valve. Twelve resected valves were examined. INTERVENTIONS--Percutaneous balloon dilatation of the aortic valve (maximal balloon size: trefoil 3 x 12 mm balloon or bifoil 2 x 19 mm balloon) and surgical inspection before excision of the aortic valve leaflets during open-chest aortic valve replacement. Fixation, decalcification, and staining for histology. MAIN OUTCOME MEASURES--Presence of long-term pathological changes in the resected valve and their relation to restenosis after balloon dilatation. RESULTS--Macroscopically the previously dilated valves were indistinguishable from valves from the patients who had valve replacement only. Microscopically, the dilated aortic valves showed areas of young scar tissue that were not seen in a control group of surgically excised stenotic aortic valves. This persistent scarring reaction was seen around small tears or lacerations of the collagenous valve stroma, fractures in calcified areas, and splits in commissures. Young scar tissue without collagenisation was still present 24 months after dilatation. CONCLUSION--Organisation and collagenisation of scar tissue develops slowly after balloon dilatation of the aortic valve. This prolonged scarring reaction may explain the late development of restenosis in some patients.Keywords
This publication has 16 references indexed in Scilit:
- Determinants of one-year outcome from balloon aortic valvuloplastyThe American Journal of Cardiology, 1991
- Clinical and Doppler echocardiographic follow-up after percutaneous balloon valvuloplasty for aortic valve stenosisThe American Journal of Cardiology, 1991
- Assessment of the “long sheath” technique for percutaneous aortic balloon valvuloplastyCatheterization and Cardiovascular Diagnosis, 1990
- Valve injury and repair in balloon aortic valvuloplastyCatheterization and Cardiovascular Diagnosis, 1989
- Pathology of aortic valvuloplasty: Findings after postmortem successful and failed dilatationsAmerican Heart Journal, 1989
- Balloon Aortic Valvuloplasty in 170 Consecutive PatientsNew England Journal of Medicine, 1988
- Computed Tomography During Experimental Balloon Dilatation For Calcific Aortic Stenosis. A Look into the Mechanism of ValvuloplastyJournal of Interventional Cardiology, 1988
- Restenosis 3 months after successful percutaneous aortic valvoplasty. A clinicopathological reportInternational Journal of Cardiology, 1987
- Treatment of calcific aortic stenosis by balloon valvuloplastyThe American Journal of Cardiology, 1987
- PERCUTANEOUS TRANSLUMINAL VALVULOPLASTY OF ACQUIRED AORTIC STENOSIS IN ELDERLY PATIENTS: AN ALTERNATIVE TO VALVE REPLACEMENT?The Lancet, 1986