The electric resistivity of human tissues (100 Hz-10 MHz): a meta-analysis of review studies
- 1 November 1999
- journal article
- research article
- Published by IOP Publishing in Physiological Measurement
- Vol. 20 (4) , R1-R10
- https://doi.org/10.1088/0967-3334/20/4/201
Abstract
The electric resistivity of various human tissues has been reported in many studies, but on comparison large differences appear between these studies. The aim of this study was to investigate systematically the resistivities of human tissues as published in review studies (100 Hz-10 MHz). A data set of 103 resistivities for 21 different human tissues was compiled from six review studies. For each kind of tissue the mean and its 95% confidence interval were calculated. Moreover, an analysis of covariance showed that the calculated means were not statistically different for most tissues, namely skeletal (171 cm) and cardiac (175 cm) muscle, kidney (211 cm), liver (342 cm), lung (157 cm) and spleen (405 cm), with bone (>17 583 cm), fat (3850 cm) and, most likely, the stratum corneum of the skin having higher resistivities. The insignificance of differences between various tissue means could imply an equality of their resistivities, or, alternatively, could be the result of the large confidence intervals which obscured real existing differences. In either case, however, the large 95% confidence intervals reflected large uncertainties in our knowledge of resistivities of human tissues. Applications based on these resistivities in bioimpedance methods, EEG and EKG, should be developed and evaluated with these uncertainties in mind.Keywords
This publication has 26 references indexed in Scilit:
- Sensitivity Distributions of Impedance Cardiography Using Band and Spot Electrodes Analyzed by a Three-Dimensional Computer ModelAnnals of Biomedical Engineering, 1998
- The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissuesPhysics in Medicine & Biology, 1996
- The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHzPhysics in Medicine & Biology, 1996
- The dielectric properties of biological tissues: I. Literature surveyPhysics in Medicine & Biology, 1996
- Statistics notes: Transformations, means, and confidence intervalsBMJ, 1996
- Finite element models of thoracic conductive anatomy: sensitivity to changes in inhomogeneity and anisotropyIEEE Transactions on Biomedical Engineering, 1994
- The specific resistance of blood at body temperatureMedical & Biological Engineering & Computing, 1973
- The specific resistance of biological material—A compendium of data for the biomedical engineer and physiologistMedical & Biological Engineering & Computing, 1967
- Specific Electric Resistance of Body TissuesPhysics in Medicine & Biology, 1961
- THE HIGH FREQUENCY RESISTANCE OF HUMAN TISSUEAmerican Journal of Physiology-Legacy Content, 1932