Comparison of errors associated with single- and multi-bolus injection protocols in low-temporal-resolution dynamic contrast-enhanced tracer kinetic analysis
- 1 September 2006
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 56 (3) , 611-619
- https://doi.org/10.1002/mrm.20971
Abstract
Accurate sampling of the arterial input function (AIF) in low-temporal-resolution quantitative dynamic contrast-enhanced MRI (DCE-MRI) studies is crucial for accurate and reproducible parameter estimation. However, when conventional AIFs are sampled at low temporal resolution, they introduce an unpredictable degree of error. An alternative double contrast agent (CA) bolus injection protocol designed to compensate for temporal mis-sampling of the AIF and tissue uptake curve was simulated in addition to a commonly used single CA bolus injection protocol. A range of tissue uptake curves for each AIF form were generated using a distributed parameter model, and Monte Carlo simulation studies were performed over a range of offset times (to mimic temporal mis-sampling), temporal resolutions and SNR in order to compare the performance of both AIF forms in compartmental modeling. Insufficient data sampling of the single bolus AIF at temporal resolutions in excess of 9 s leads to large errors, which can be reduced by employing an additional, appropriately administered, second CA bolus injection.Keywords
This publication has 31 references indexed in Scilit:
- Quantifying dynamic contrast‐enhanced MRI of the knee in children with juvenile rheumatoid arthritis using an arterial input function (AIF) extracted from popliteal artery enhancement, and the effect of the choice of the AIF on the kinetic parametersMagnetic Resonance in Medicine, 2005
- Dynamic Contrast-Enhanced Magnetic Resonance Imaging in OncologyPublished by Springer Nature ,2005
- Contrast-enhanced dynamic and static MRI correlates with quantitative 99Tcm-labelled nanocolloid scintigraphy. Study of early rheumatoid arthritis patientsRheumatology, 2004
- Estimating the arterial input function using two reference tissues in dynamic contrast‐enhanced MRI studies: Fundamental concepts and simulationsMagnetic Resonance in Medicine, 2004
- Carotid Artery Atherosclerosis: In Vivo Morphologic Characterization with Gadolinium-enhanced Double-oblique MR Imaging—Initial ResultsRadiology, 2002
- Effects of Androgen Deprivation on Prostatic Morphology and Vascular Permeability Evaluated with MR ImagingRadiology, 2001
- An Adiabatic Approximation to the Tissue Homogeneity Model for Water Exchange in the Brain: II. Experimental ValidationJournal of Cerebral Blood Flow & Metabolism, 1998
- Measurement of the arterial concentration of Gd‐DTPA using MRI: A step toward quantitative perfusion imagingMagnetic Resonance in Medicine, 1996
- Measurement of the blood‐brain barrier permeability and leakage space using dynamic MR imaging. 1. Fundamental conceptsMagnetic Resonance in Medicine, 1991
- Quantitation of blood‐brain barrier defect by magnetic resonance imaging and gadolinium‐DTPA in patients with multiple sclerosis and brain tumorsMagnetic Resonance in Medicine, 1990