Quantification of the inflammatory response in exudates to three polymers implantedin vivo
- 15 March 1998
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 39 (4) , 637-641
- https://doi.org/10.1002/(sici)1097-4636(19980315)39:4<637::aid-jbm19>3.0.co;2-3
Abstract
Flow cytometry was used to quantify an inflammatory reaction in vivo as a new approach to evaluating the biocompatibility of biomaterials. The exudate formed inside cylindrical tubes composed of polyvinyl chloride (PVC), silicone elastomer (SIL), or polyurethane (PU) implanted subcutaneously in the dorsal region of rats was collected over a 3-week period. The volume, number of cells, and concentration of fibrinogen were determined in the exudate for the three biomaterials. The exudate was analyzed using a flow cytometry technique after labeling of the leukocytes with a monoclonal anti-CD45 antibody. Fibrinogen rose progressively over the 3-week period for the three polymers. After the different leukocyte lines were identified in rat blood samples, their determination in the exudate revealed differences among the three biomaterials. At day 2, PVC induced a predominantly neutrophilic inflammatory reaction whereas PU and SIL gave a mixture of monocytes and neutrophils. At day 9, the aspect of the cytograms was different, but the identification of the subpopulations was still possible. At day 23, the number of cell events became too low to distinguish the subpopulations. An even more detailed approach might be possible using specific labeling for each leukocyte line to establish a comparison among the three biomaterials. Flow cytometry associated with histomorphometric assessment might provide a precise quantitative in vivo test for determining the biocompatibility of materials. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res, 39, 637–641, 1998.Keywords
This publication has 13 references indexed in Scilit:
- Distribution of cells in soft tissue and fluid space around hollow and solid implants in the ratJournal of Materials Science: Materials in Medicine, 1994
- Tissue reactions to subcutaneously implanted, surface‐modified siliconesJournal of Biomedical Materials Research, 1993
- CD45 Gating for Routine Flow Cytometric Analysis of Human Bone Marrow SpecimensAnnals of the New York Academy of Sciences, 1993
- Image analysis in the evaluation of biomaterialsJournal of Biomedical Engineering, 1993
- A method of analysis of cellular distribution in the membrane encapsulating surgically implanted biomaterialsJournal of Applied Biomaterials, 1990
- In vitro and in vivo interactions of cells with biomaterialsBiomaterials, 1988
- Tissue-biomaterial interactionsJournal of Materials Science, 1987
- In vivo biocompatibility studies. VII. Inflammatory response to polyethylene and to a cytotoxic polyvinylchlorideJournal of Biomedical Materials Research, 1986
- Biomaterial biocompatibility and the macrophageBiomaterials, 1984
- Biocompatibility testing of polymers: In vitro studies with in vivo correlationJournal of Biomedical Materials Research, 1978