A new approach to data reduction and evaluation in high‐resolution time‐of‐flight mass spectrometry using a time‐to‐digital convertor data‐recording system
- 2 April 2001
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 15 (8) , 570-578
- https://doi.org/10.1002/rcm.262
Abstract
A new effective and robust approach to the detection of incompletely resolved peaks, and evaluation of their parameters in high‐resolution time‐of‐flight mass spectra for time‐to‐digital convertor (TDC) data acquisition mode, is described. The method is based on fast construction of a smoothed continuous curve that approximates the initial data (transformed to a constant relative width of time intervals for ion counting) with respect to precision of measurements. The first derivative of this curve is used for correction of skewness of the peak shape as far as possible. A contribution of the second derivative is subtracted from the smoothed curve for better resolution of partially resolved peaks. The comparison of local maxima of this resulting final curve with those for the initial smoothed curve allows reliable detection of the peaks and to test whether or not they are spoiled by overlapping. Ion counting performed by TDC gives an opportunity to estimate standard deviations of peak locations and their intensities. These values proved to be close to theoretically minimal standard deviations for these parameters for single fully resolved peaks. Thus, estimates of the main parameters of mass peaks by the described method are close to statistically efficient estimators for these parameters. Copyright © 2001 John Wiley & Sons, Ltd.Keywords
This publication has 8 references indexed in Scilit:
- High-Resolution Electrospray Ionization Orthogonal-Injection Time-of-Flight Mass SpectrometerEuropean Journal of Mass Spectrometry, 2000
- Automated reduction and interpretation ofPublished by American Chemical Society (ACS) ,2000
- Assignment of the mass number to peaks in high-resolution mass spectra acquired via the counting of ionsInternational Journal of Mass Spectrometry and Ion Processes, 1988
- Deconvolution of overlapping mass spectral peaks following ion-counting data acquisitionInternational Journal of Mass Spectrometry and Ion Processes, 1985
- Data acquisition and processing in high-resolution mass spectrometry using ion countingInternational Journal of Mass Spectrometry and Ion Physics, 1977
- Resolution enhancement of chromatograph peaksAnalytical Chemistry, 1971
- Novel sample modulation device for flame spectrometry and evaluation of its utility for noise reductionAnalytical Chemistry, 1970
- Smoothing and Differentiation of Data by Simplified Least Squares Procedures.Analytical Chemistry, 1964