Subject variability of shoulder abduction strength testing
- 1 July 1990
- journal article
- research article
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 18 (4) , 349-353
- https://doi.org/10.1177/036354659001800403
Abstract
To quantify normal biological variability of shoulder abduction strength testing with an isokinetic and a hand-held dynamometer, we tested nine healthy sub jects over a clinically relevant period. One side was tested with a Cybex at 60 deg/sec and the other with a hand-held dynamometer. Six maximal trials, following warmup, were conducted on each of 5 days, separated by 1 to 2 weeks. Intraday correlations of individual trials ranged from 0.82 to 0.995 for hand-held dynamometer, and 0.88 to 0.996 for Cybex. Interday correlations ranged from 0.94 to 0.98 for hand-held dynamometer, and 0.88 to 0.97 for Cybex. The best values to use for Cybex interday variability were the average of the first three repetitions, and yielded standard errors of 8.6% to 19.2% of the sample mean. The average of the last three repetitions were the best for hand-held dynamom eters, and yielded standard errors of 5.5% to 10.8%. There was a significant decline (P < 0.05) in strength of the mean of the last three versus the mean of the first three daily repetitions on Day 1 and 4 for hand- held dynamometers, and a trend toward this on the other days, that was not seen with Cybex. Regression of average Day 1 values for Cybex and hand-held dynamometer yielded r = 0.86 (P < 0.01) with a slope of 1.07 indicating good agreement between modalities. In conclusion, intraday/interday correlations were high for Cybex and hand-held dynamometer. Interday vari ability was minimized by using the mean score of the first three and last three repetitions for Cybex and hand- held dynamometer, respectively. Changes in Cybex and hand-held dynamometer strength of less than 19% and 11 %, respectively, are within the area of "measurement error" and should therefore not be considered clinically significant.This publication has 20 references indexed in Scilit:
- Calibration Study: Accuracy of Spring and Strain Gauge Hand-Held DynamometersJournal of Orthopaedic & Sports Physical Therapy, 1989
- Reliability of an Isokinetic Test of Muscle Strength and EnduranceJournal of Orthopaedic & Sports Physical Therapy, 1989
- Reliability of a Reciprocal Test Protocol Performed on the Kinetic Communicator: An Isokinetic Test of Knee Extensor and Flexor StrengthJournal of Orthopaedic & Sports Physical Therapy, 1988
- Intrarater and Interrater Reliability of Strength Measurements of the Biceps and Deltoid Using a Hand Held DynamometerJournal of Orthopaedic & Sports Physical Therapy, 1988
- Hand-held dynamometry; stability of muscle strength over multiple measurementsClinical Biomechanics, 1987
- Reliability of Isokinetic Muscle Endurance TestsJournal of Orthopaedic & Sports Physical Therapy, 1987
- Comparison of Peak Torque Values of the Knee Flexor and Extensor Muscle Groups Using the Cybex II®and Lido 2.0®Isokinetic DynamometersJournal of Orthopaedic & Sports Physical Therapy, 1987
- RELIABILITY OF MAXIMAL ISOKINETIC STRENGTH AND WORK MEASURESMedicine & Science in Sports & Exercise, 1985
- Myofibrillar Damage Following Intense Eccentric Exercise in ManInternational Journal of Sports Medicine, 1983
- Measurements of muscle strength and performance in children with normal and diseased muscle.Archives of Disease in Childhood, 1976