Glucose Biosensor Based on Oxygen Electrode. Part II: Long-Term Operational Stability of the Rechargeable Glucose Biosensor
- 1 October 1993
- journal article
- chemical and-biosensors
- Published by Taylor & Francis in Analytical Letters
- Vol. 26 (10) , 2079-2094
- https://doi.org/10.1080/00032719308017453
Abstract
A potentially implantable glucose biosensor for measuring blood or tissue glucose levels in diabetic patients has been developed. The glucose biosensor is based on an amperometric oxygen electrode and immobilized glucose oxidase enzyme, in which the immobilized enzyme can be replaced (the sensor recharged) without surgical removal of the sensor from the patient. Recharging of the sensor is achieved by injecting fresh immobilized enzyme into the sensor using a septum. A special technique for immobilization of the enzyme on Ultra-Low Temperature Isotropic (ULTI) carbon powder held in a liquid suspension has been developed. In vitro studies of the sensors show stable performance during several recharge cycles over a period of 3 months of continuous operation. Diffusion membranes which ensure linear dependence of the sensor response on glucose concentration have been developed. These membranes comprise silastic latex-rubber coatings over a microporous polycarbonate membrane. Calibration curves of the amperometric signal show linearity over a wide range of glucose concentrations (up to 16 mM), covering hypoglycemic, normoglycemic and hyperglycemic conditions. The experimental results confirm the suitability of the sensors for in vitro measurements in undiluted human sera.Keywords
This publication has 17 references indexed in Scilit:
- Implantable Programmable Insulin Pumps for the Treatment of DiabetesArchives of Surgery, 1992
- Towards continuous glucose monitoring: in vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissueDiabetologia, 1992
- Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoringAnalytical Chemistry, 1991
- A Preliminary Trial of the Programmable Implantable Medication System for Insulin DeliveryNew England Journal of Medicine, 1989
- In vivo measurement of subcutaneous glucose concentrations with an enzymatic glucose sensor and a wick methodJournal of Molecular Medicine, 1989
- In vitro and in vivo stability of electrode potentials in needle-type glucose sensors. Influence of needle materialDiabetes, 1989
- Telemetry Glucose Monitoring Device With Needle-Type Glucose Sensor: A Useful Tool for Blood Glucose Monitoring in Diabetic IndividualsDiabetes Care, 1986
- Technology and the diabetic patientMedical & Biological Engineering & Computing, 1984
- An Implantable Electrochemical Glucose SensoraAnnals of the New York Academy of Sciences, 1984
- Implanted Electroenzymatic Glucose SensorsDiabetes Care, 1982