The Immune Response to Implant Materials in Humans
- 1 May 1996
- journal article
- research article
- Published by Wolters Kluwer Health
- Vol. 326 (326) , 63-70
- https://doi.org/10.1097/00003086-199605000-00008
Abstract
The etiology of aseptic loosening of prosthetic joint replacement components is unclear. Implant materials have been considered biologically inert, but recently studies indicate that inflammatory reactions directed against the implanted materials may contribute to aseptic loosening. Data suggesting a progression from a simple inflammatory reaction to complex immune responses against the biomaterials are reviewed. The cellular responses to particles of polymethylmethacrylate, ultrahigh molecular weight polyethylene, and alloys of cobalt-chromium and titanium were assayed in vitro to determine cell proliferation in patients with underlying diagnoses of osteoarthrosis, rheumatoid arthritis, and avascular necrosis who had joint replacement. Control populations were provided by patients with similar diagnoses who were preoperative surgical candidates. The underlying diagnoses did not seem to influence responses to particle stimulation. Elevated responses to both acrylic and cobalt-chromium were observed in patients with aseptically loosened prostheses. These findings suggest that the development of a cellular response to particulate debris may be significant in the pathogenesis of aseptic loosening.Keywords
This publication has 13 references indexed in Scilit:
- Cellular proliferation and cytokine responses to polymethylmethacrylate particles in patients with a cemented total joint arthroplastyInflammation Research, 1995
- Immunocytochemical localization of inflammatory cytokines and vascular adhesion receptors in radicular cystsJournal of Oral Pathology & Medicine, 1993
- Cytokines in autoimmunityCurrent Opinion in Immunology, 1992
- Lymphocyte response to polymethylmethacrylate in loose total hip prosthesesThe Journal of Bone and Joint Surgery. British volume, 1992
- Quantitative comparison of the histological effects of particulate polymethylmethacrylate versus polyethylene in the rabbit tibiaArchives of orthopaedic and trauma surgery, 1991
- Differential effects of eight metal ions on lymphocyte differentiation antigens in vitroJournal of Biomedical Materials Research, 1990
- PROSTHESIS-ASSOCIATED PSEUDOMEMBRANE-INDUCED BONE RESORPTIONRheumatology, 1990
- Changes Seen in Lymph Nodes Draining the Sites of Large Joint ProsthesesThe American Journal of Surgical Pathology, 1989
- Stimulation of bone resorption and inhibition of bone formation in vitro by human tumour necrosis factorsNature, 1986
- An interleukin 1 like factor stimulates bone resorption in vitroNature, 1983