A comparison of three clinical methods of spatial contrast-sensitivity testing in normal subjects
- 1 January 1990
- journal article
- research article
- Published by Springer Nature in Albrecht von Graefes Archiv für Ophthalmologie
- Vol. 228 (1) , 24-27
- https://doi.org/10.1007/bf02764285
Abstract
Three methods clinically used for measuring spatial contrast sensitivity were performed monocularly in normal subjects to compare their sensitivity and applicability. The methods tested were (1) the Von Békésy tracking procedure, (2) the Method of Increasing Contrast, both carried out on a Nicolet CS-2000 automated Vision Tester, and (3) the Vistech Contrast Test System, a photographic test chart. The results show that the threshold sensitivities of the Von Békésy tracking procedure and the Method of Increasing Contrast were not significantly different. For sensitivity to middle and high spatial frequency, the Vistech test chart was found to approximate the Method of Increasing Contrast. With automated testing, a slower rate of contrast progression and a larger visual angle produced lower thresholds of detection of the contrast-sensitivity function. Using a slow rate of contrast progression, both the Vistech test chart and the Method of Increasing Contrast were rapidly conducted, easy to administer, and gave good approximations of the spatial contrast-sensitivity function.Keywords
This publication has 8 references indexed in Scilit:
- Contrast Sensitivity Testing in Pseudotumor CerebriOphthalmology, 1986
- A New Contrast Sensitivity Vision Test ChartOptometry and Vision Science, 1984
- Large-Sample Norms for Contrast SensitivityOptometry and Vision Science, 1984
- The 20/20 eye in multiple sclerosisNeurology, 1983
- Comparison of three methods for rapid determination of threshold contrast sensitivity.1983
- Optic Nerve Damage in Human GlaucomaArchives of Ophthalmology (1950), 1982
- How good is normal visual acuity?Albrecht von Graefes Archiv für Ophthalmologie, 1981
- The influence of the number of cycles upon the visual contrast threshold for sptial sine wave patternsVision Research, 1974