Minimally Invasive Extraction of Dermal Interstitial Fluid for Glucose Monitoring Using Microneedles
Top Cited Papers
- 1 February 2005
- journal article
- Published by Mary Ann Liebert Inc in Diabetes Technology & Therapeutics
- Vol. 7 (1) , 131-141
- https://doi.org/10.1089/dia.2005.7.131
Abstract
Compliance with glucose monitoring by patients with diabetes is poor because of the pain and inconvenience of conventional blood collection using lancets. To improve compliance, and thereby reduce morbidity and mortality associated with poor glucose control, this study sought to develop and test minimally invasive microneedles to extract dermal interstitial fluid (ISF) for glucose monitoring. We used a thermal puller to fabricate individual or multi-needle arrays of glass microneedles with tip radii of 15-40 microm to penetrate 700-1,500 microm deep into the skin of anesthetized hairless rats or conscious, normal, adult, human subjects. After applying a vacuum of 200-500 mm Hg for 2-10 min, we extracted ISF and measured glucose concentration. These measurements were compared with glucose levels in blood collected from the tail vein of rats or finger stick on humans. Using this procedure, 1-10 microL of ISF was extracted out of holes punctured in the skin using microneedles. Human subjects generally reported the procedure as painless. ISF glucose concentration correlated well with blood levels based on 140 measurements on 15 rats and six measurements on six human subjects, where 95% of rat data and 100% of human data fell within the clinically acceptable A + B region in Clarke Error Grid analysis. A linear calibration factor was needed to correlate ISF and blood glucose concentrations using our standard procedure. Modifying the procedure to prevent ISF evaporation during extraction provided a one-to-one correlation that eliminated the need for calibration. ISF glucose measurements tracked rapidly changing blood glucose levels following insulin injection with a time lag of less than 20 min. These results suggest that microneedle devices can be used to extract ISF for painless glucose monitoring.Keywords
This publication has 30 references indexed in Scilit:
- Analysis: Glucose Monitoring by Reverse IontophoresisDiabetes Technology & Therapeutics, 2000
- Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33)The Lancet, 1998
- Development of Noninvasive Methods to Monitor Blood Glucose Levels in People With DiabetesJAMA, 1998
- Glucose measurement in patients with diabetes mellitus with dermal interstitial fluidJournal of Laboratory and Clinical Medicine, 1997
- Dermal Interstitial Glucose as an Indicator of Ambient GlycemiaDiabetes Care, 1997
- Noninvasive Blood Glucose MonitoringDiabetes Care, 1997
- Non-invasive glucose monitoringCurrent Opinion in Biotechnology, 1996
- The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes MellitusNew England Journal of Medicine, 1993
- Noninvasive optical polarimetric glucose sensing using a true phase measurement techniqueIEEE Transactions on Biomedical Engineering, 1992
- Noninvasive Sampling of Biological Fluids by IontophoresisPharmaceutical Research, 1989