Detection of Chlamydia trachomatis in Genitourinary Tract Specimens Using an Automated Enzyme-Linked Fluorescent Immunoassay
- 1 March 1996
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Sexually Transmitted Diseases
- Vol. 23 (2) , 115-119
- https://doi.org/10.1097/00007435-199603000-00005
Abstract
The VIDAS Enzyme Linked Fluorescent Assay is a fully automated assay for the detection of Chlamydia trachomatis in clinical specimens. Because there is an increasing demand for automated assays for large volume laboratories and there is little performance data available, the authors evaluated the performance of the VIDAS enzyme linked fluorescent assay by comparing it with Chlamydiazyme and polymerase chain reaction. Endocervical swabs from 330 women attending a hospital based obstetrics/gynecology clinic and 100 first void urine specimens from males attending a sexually transmitted disease clinic were tested by enzyme linked fluorescent assay, Chlamydiazyme, and polymerase chain reaction. Fourteen of 330 endocervical specimens and 14 of 100 first void urine specimens were positive by Chlamydiazyme. Enzyme linked fluorescent assay detected 12 of 14 endocervical and 11 of 14 first void urine specimens. Compared with Chlamydiazyme, enzyme linked fluorescent assay had a sensitivity of 85.7% (12 of 14) for endocervical swabs and 76.9% (11 of 14) for first void urine specimens. Polymerase chain reaction detected an additional five endocervical and two first void urine specimens that had negative results by both enzyme linked fluorescent assay and Chlamydiazyme. All 7 were confirmed positive by polymerase chain reaction using a second primer set. Using an expanded gold standard of blocked Chlamydiazyme and confirmed polymerase chain reaction, enzyme linked fluorescent assay had a sensitivity of 63.2% (12 of 19) for endocervical swabs and 68.8% (11 of 16) for first void urine specimens compared with 73.7% (14 of 19) and 87.5% (14 of 16) for Chlamydiazyme. Polymerase chain reaction had a sensitivity of 100% (19 of 19) and 93.8% (15 of 16) for endocervical swabs and first void urine specimens, respectively. The specificity of enzyme linked fluorescent assay and Chlamydiazyme was 100%. The VIDAS enzyme linked fluorescent assay for the detection of Chlamydia trachomatis in genitourinary specimens is highly specific but is not sufficiently sensitive for use as a routine diagnostic test.Keywords
This publication has 13 references indexed in Scilit:
- Evaluation of urogenitalChlamydia trachomatis infections by cell culture and the polymerase chain reaction using a closed systemEuropean Journal of Clinical Microbiology & Infectious Diseases, 1991
- Detection of Chlamydia trachomatis by the polymerase chain reaction in swabs and urine from men with non-gonococcal urethritis.Journal of Clinical Pathology, 1991
- Detection ofChlamydia trachomatis in clinical specimens by the polymerase chain reactionEuropean Journal of Clinical Microbiology & Infectious Diseases, 1990
- Screening asymptomatic adolescent males for chlamydiaJournal of Adolescent Health, 1990
- Detection of Chlamydia trachomatis Antigens in Urine as an Alternative to Swabs and CulturesThe Journal of Infectious Diseases, 1990
- Avoiding false positives with PCRNature, 1989
- Why We Need a Program for the Control ofChlamydia trachomatisNew England Journal of Medicine, 1989
- Asymptomatic Chlamydia trachomatis infections in teenage malesJournal of Adolescent Health, 1988
- Chlamydia trachomatis in suburban adolescentsThe Journal of Pediatrics, 1987
- Rapid diagnosis of sexually transmitted diseases—Speed has a priceDiagnostic Microbiology and Infectious Disease, 1986