An Implanted Upper-Extremity Neuroprosthesis. Follow-up of Five Patients*
- 1 April 1997
- journal article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 79 (4) , 533-41
- https://doi.org/10.2106/00004623-199704000-00008
Abstract
An implanted neuroprosthesis supplying functional neuromuscular stimulation was used to provide grasp and release to tetraplegic individuals. This article describes the results, at a minimum of three years, for the first five patients to have operative implantation of an eight-channel stimulator-receiver. All of the patients had a clinically complete spinal cord injury with motor function remaining at the level of the fifth or sixth cervical nerve root.In addition to implantation of the stimulator system, each patient had augmentative operations on the hand to improve function. The procedures included tendon transfers, side-to-side tendon anastomoses, arthrodesis of the interphalangeal joint of the thumb, and rotational osteotomy of the radius.The neuroprosthesis provides two grasp patterns controlled by voluntary motion of the shoulder or wrist. Functional evaluations included measurement of pinch force, a grasp-release test, evaluation of the level of functional independence, and usage surveys. Pinch force ranged from eight to twenty-five newtons. All five patients demonstrated functional grasp patterns, had increased independence, and were able to use the neuroprosthesis at home on a regular basis. The implanted stimulator has proved to be safe and reliable, with seven years as the longest time in situ at the time of writing.Keywords
This publication has 21 references indexed in Scilit:
- Development of a quantitative hand grasp and release test for patients with tetraplegia using a hand neuroprosthesisThe Journal of Hand Surgery, 1994
- An analysis of the reliability of percutaneous intramuscular electrodes in upper extremity FNS applicationsIEEE Transactions on Rehabilitation Engineering, 1993
- Pacemaker Twiddler's Syndrome: A case reportThe American Journal of Emergency Medicine, 1990
- Evaluation of shoulder movement as a command control sourceIEEE Transactions on Biomedical Engineering, 1990
- Electrode characterization for functional application to upper extremity FNSIEEE Transactions on Biomedical Engineering, 1990
- Implantable functional neuromuscular stimulation in the tetraplegic handThe Journal of Hand Surgery, 1989
- The Second International Conference on Surgical Rehabilitation of the Upper Limb in Tetraplegia (Quadriplegia)The Journal of Hand Surgery, 1986
- Brachioradialis to flexor pollicis longus tendon transfer for active lateral pinch in the tetraplegicThe Journal of Hand Surgery, 1985
- Restoration of strong grasp and lateral pinch in tetraplegia: A comparison of two methods of thumb control in each patientThe Journal of Hand Surgery, 1985
- Controlled prehension and release in the C5 quadriplegic elicited by functional electrical stimulation of the paralyzed forearm musculatureAnnals of Biomedical Engineering, 1980