The Coventry Award Paper: Factors Influencing Wear and Osteolysis in Press-Fit Condylar Modular Total Knee Replacements
- 1 November 2004
- journal article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 428 (428) , 40-50
- https://doi.org/10.1097/01.blo.0000148853.37270.67
Abstract
The purpose of this study was to determine the factors influencing wear and osteolysis in patients who have had total knee arthroplasty with the Press-Fit Condylar modular system. Two-thousand ninety-one primary total knee replacements in 1737 patients were done using the Press-Fit Condylar system at three centers. Radiographic and manufacturing data were obtained for 2016 of the 2091 implants (96.4%). For the 1287 of 2016 knees (64%) with more than 5 years of followup, the prevalence of wear-related failure was 8.3%. The 13-year survivorship for all patients was 82.6%. Cox hazards analysis revealed five variables that were correlated with wear-related failure: patient age, patient gender, polyethylene sheet vendor, polyethylene finishing method, and polyethylene shelf age. We were unable to identify one factor as the defining reason for these wear-related failures. The multiple changes in manufacturing methods during the life of this implant may have precluded such a determination. These results may be specific to inserts sterilized in air with gamma irradiation and should not be generalized to current manufacturing techniques. This study emphasizes the potential deleterious effects that small changes in the manufacturing process may have on the outcome of a prosthesis with an initially favorable survivorship.Keywords
This publication has 31 references indexed in Scilit:
- RADIOGRAPHIC DEFINITION OF PELVIC OSTEOLYSIS FOLLOWING TOTAL HIP ARTHROPLASTYJournal of Bone and Joint Surgery, 2003
- SURFACE DAMAGE IN MACHINED RAM-EXTRUDED AND NET-SHAPE MOLDED RETRIEVED POLYETHYLENE TIBIAL INSERTS OF TOTAL KNEE REPLACEMENTSJournal of Bone and Joint Surgery, 2002
- Long-Term Followup of the Miller-Galante Total Knee ReplacementClinical Orthopaedics and Related Research, 2001
- The Press-Fit Condylar total knee systemThe Journal of Arthroplasty, 2000
- Cemented Rotating-Platform Total Knee ReplacementJournal of Bone and Joint Surgery, 2000
- Effect of fabrication method and resin type on performance of tibial bearingsJournal of Biomedical Materials Research, 2000
- The Effects of Shelf Life on Clinical Outcome for Gamma Sterilized Polyethylene Tibial ComponentsClinical Orthopaedics and Related Research, 1999
- Shelf Life and In Vivo Duration; Impacts on Performance of Tibial BearingsClinical Orthopaedics and Related Research, 1997
- Impact of gamma sterilization on clinical performance of polyethylene in the kneeThe Journal of Arthroplasty, 1996
- The posterior stabilized total knee prosthesis. Assessment of polyethylene damage and osteolysis after a ten-year-minimum follow-up.Journal of Bone and Joint Surgery, 1995