To prospectively use compact avalanche photodiodes instead of photomultiplier tubes to integrate a positron emission tomographic (PET) detector and a 7-T magnetic resonance (MR) imager. All animal experiments were performed in accordance with the University of Tübingen guidelines and the German law for the protection of animals. A compact lutetium oxyorthosilicate-avalanche photodiode PET detector was built and optimized to operate within a 7-T MR imager. The detector performance was investigated both outside and inside the magnet, and MR image quality was evaluated with and without the PET detector. Two PET detectors were set up opposite each other and operated in coincidence to acquire PET images in the step-and-shoot mode in a mouse head specimen after injection of fluorine 18 fluorodeoxyglucose. The performance of the PET detector when operated inside the magnet during MR image acquisition showed little degradation in energy resolution (increase from 14.6% to 15.9%). The PET detector did not influence MR imaging. The fused PET and MR images showed an anatomic match and no degradation of image quality. Simultaneous PET and MR imaging with a 7-T system was deemed feasible.Keywords
This publication has 18 references indexed in Scilit:
- Depth of interaction resolution measurements for a high resolution PET detector using position sensitive avalanche photodiodesPhysics in Medicine & Biology, 2006
- Diagnostic Performance of Whole Body Dual Modality 18F-FDG PET/CT Imaging for N- and M-Staging of Malignant Melanoma: Experience With 250 Consecutive PatientsJournal of Clinical Oncology, 2006
- A block detector for a multislice, depth-of-interaction MR-compatible PETIEEE Transactions on Nuclear Science, 2005
- Accuracy of Whole-Body Dual-Modality Fluorine-18–2-Fluoro-2-Deoxy-d-Glucose Positron Emission Tomography and Computed Tomography (FDG-PET/CT) for Tumor Staging in Solid Tumors: Comparison With CT and PETJournal of Clinical Oncology, 2004
- A prototype high-resolution animal positron tomograph with avalanche photodiode arrays and LSO crystalsEuropean Journal of Nuclear Medicine and Molecular Imaging, 2001
- Design of a small animal MR compatible PET scannerIEEE Transactions on Nuclear Science, 1999
- Magnetic shielding requirements for PET detectors during transcranial magnetic stimulationIEEE Transactions on Nuclear Science, 1998
- Simultaneous PET and MR imagingPhysics in Medicine & Biology, 1997
- Development of a PET detector system compatible with MRI/NMR systemsIEEE Transactions on Nuclear Science, 1997
- Initial results from the Sherbrooke avalanche photodiode positron tomographIEEE Transactions on Nuclear Science, 1996