Thermal properties of capacitively coupled electrodes in interstitial hyperthermia
- 1 January 1998
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 43 (1) , 139-153
- https://doi.org/10.1088/0031-9155/43/1/009
Abstract
The multi-electrode current source (MECS) interstitial hyperthermia system, which is used for treatment of cancer, employs segmented electrodes inserted in plastic tubes implanted in the treatment volume. The mean power deposition of the individual electrodes is controlled by varying the duty cycle of the RF signal applied to the electrodes, using thermocouples inside the electrodes for thermometry. A non-zero loss angle results in self-heating of the catheter. The thermal influence of self-heating was investigated and an analysis of the measurement of temperatures inside the catheter during and after heating is presented. Analytical models and a high-resolution numerical model were used for the calculation of steady state and transient distributions, respectively. The model results are compared with experimental data obtained in a muscle equivalent phantom. Results indicate that there is no difference between temperature inside and outside the catheter when using lossless catheter materials (e.g. PE and PTFE). Self-heating in the catheter wall has an adverse effect on the uniformity of the stationary temperature distribution and the reliability of temperature measurement with internal thermometry. These problems remain within acceptable limits for mildly lossy materials; the difference between the temperature inside and outside is only 6% when using low-loss Nylon. Analysis of the thermal decay after power-off shows that low-loss materials allow more time to obtain an accurate estimate of the tissue temperature at the catheter wall during power-on. This effect is enhanced by the presence of minute air layers in the applicator. Distortion of temperature gradients along the catheter was also investigated. Key factors are the thermal conduction across the catheter wall, and especially the presence of minute layers of air between consecutive layers of the probe. The distortion extends less than two millimetres, which is acceptable. The simulation results are compatible with measurements in phantoms and show that, if the proper choice of materials is made, the MECS applicator answers our expectations and that the temperature measurement inside the catheter can be used for direct feedback treatment control.Keywords
This publication has 17 references indexed in Scilit:
- Design of applicators for a 27 MHz multielectrode current source interstitial hyperthermia system; impedance matching and effective powerPhysics in Medicine & Biology, 1997
- Implications of using thermocouple thermometry in 27 MHz capacitively coupled interstitial hyperthermiaPhysics in Medicine & Biology, 1997
- Spatial temperature control with a 27 MHz current source interstitial hyperthermia systemInternational Journal of Radiation Oncology*Biology*Physics, 1997
- A 3-D SAR model for current source interstitial hyperthermiaIEEE Transactions on Biomedical Engineering, 1996
- The theoretical and experimental evaluation of the heat balance in perfused tissuePhysics in Medicine & Biology, 1994
- Temperature and SAR measurements in deep-body hyperthermia with thermocouple thermometryInternational Journal of Hyperthermia, 1993
- Application of a capacitive-coupling interstitial hyperthermia system at 27 MHz: study of different applicator configurationsPhysics in Medicine & Biology, 1991
- Practical interstitial method of heating operating at 27.12 MHzInternational Journal of Hyperthermia, 1989
- Perfusion analyses in advanced breast carcinoma during hyperthermiaInternational Journal of Hyperthermia, 1988
- Thermal conduction errors of manganin-constantan thermocouple arraysPhysics in Medicine & Biology, 1985